Innovative Circuit Technology Ltd.
15
the current reading will flash to indicate when the unit is operating at its current
limit.
Up/Down
Buttons:
Use to scroll through display screens, and to adjust
selected settings.
Enter Button:
Press to select a screen for adjustment, or to enter a new
value after adjustment.
Back X Button:
Press to return to the previous higher level menu item, or to exit
from a setting without making any change.
See the complete menu structure in the following diagram. Navigate through the
various screens using the up and down arrows, the back button, and the Enter
button.
The output voltage and current limit settings apply to the combined output of all
installed power modules. The ICM treats the combined modules as a single high-
power supply. Adjust the system output Voltage and Current Limit (see System
Settings section) to match the battery type and system load requirements if
required.
Figure 10: ICM Menu Structure
System Status
The main system status screen will show the most current operating conditions
for the unit, primarily the Input Voltage (Vac), the Output Voltage (Vdc), and the
total Output Current (Adc) (Flashing when at the set current limit). Other
information will be shown depending on the operating state of the unit: