background image

THE

POWER

OF

RELIABILITY

INNOVATIVE CIRCUIT TECHNOLOGY LTD.

855-040-004

ICT COMM SERIES

INSTRUCTION MANUAL

SPECIFICATIONS

Input

Voltage

Range

Available Configurations

Output

Voltage

Output

Current 

(Cont.)

Output

Current 

(Peak)

Current

Limiting

Line

Regulation

Load

Regulation

Output 

Ripple 

(Max)

Efficiency

(Typical)

AG

A

AX

ARM

AR

AM

ICT12012-8 

(1)(2)

ICT12012-10 

(1)(2)

ICT12012-11 

(1)(2)

ICT12012-12 

(1)(2)

ICT12024-5 

(1)

ICT12048-3

ICT22012-8 

(3)

ICT22012-10 

(3)

ICT22012-11 

(3)

ICT22012-12 

(3)

ICT22024-5

ICT22048-3

90-130 VAC

13.8 VDC

+/- 150 mV

6.5 Amps

8.0 Amps

8.5 Amps

0.20%

0.50%

20 mV RMS

85%

90-130 VAC

13.8 VDC

+/- 150 mV

7.5 Amps

10.0 Amps

10.5 Amps

0.20%

0.75%

20 mV RMS

85%

90-130 VAC

13.8 VDC

+/- 150 mV

9.0 Amps

11.0 Amps

11.5 Amps

0.20%

0.50%

20 mV RMS

85%

90-130 VAC

13.8 VDC

+/- 150 mV

10.0 Amps

12.0 Amps

12.5 Amps

0.20%

0.80%

20 mV RMS

85%

90-130 VAC

27.6 VDC

+/- 150 mV

4.0 Amps

5.0 Amps

5.5 Amps

0.20%

0.75%

20 mV RMS

85%

90-130 VAC

48.0 VDC

+/- 150 mV

2.5 Amps

3.0 Amps

3.5 Amps

0.50%

1.00%

20 mV RMS

85%

105-130/

180-265 VAC

13.8 VDC

+/- 150 mV

6.5 Amps

8.0 Amps

8.5 Amps

0.20%

0.50%

35 mV RMS

80%

105-130/

180-265 VAC

13.8 VDC

+/- 150 mV

7.5 Amps

10.0 Amps

10.5 Amps

0.20%

0.75%

20 mV RMS

85%

105-130/

180-265 VAC

13.8 VDC

+/- 150 mV

9.0 Amps

11.0 Amps

11.5 Amps

0.20%

0.50%

20 mV RMS

85%

105-130/

180-265 VAC

13.8 VDC

+/- 150 mV

10.0 Amps

12.0 Amps

12.5 Amps

0.20%

0.80%

20 mV RMS

85%

180-265 VAC

27.6 VDC

+/- 150 mV

4.0 Amps

5.0 Amps

5.5 Amps

0.20%

0.50%

20 mV RMS

85%

180-265 VAC

48.0 VDC

+/- 150 mV

2.5 Amps

3.0 Amps

3.5 Amps

0.50%

1.00%

35 mV RMS

80%

ICT12012-4

90-130 VAC

13.8 VDC

+/- 300mV

3.0 Amps

4.0 Amps

4.5 Amps

0.50%

2.00%

20 mV RMS

75%

ICT12012-6

90-130 VAC

13.8 VDC

+/- 300mV

4.5 Amps

6.0 Amps

6.5 Amps

0.50%

2.00%

20 mV RMS

75%

ICT22012-4

105-250 VAC

13.8 VDC

+/- 300mV

3.0 Amps

4.0 Amps

4.5 Amps

0.50%

2.00%

25 mV RMS

75%

105-250 VAC

13.8 VDC

+/- 300mV

4.5 Amps

6.0 Amps

6.5 Amps

0.50%

2.00%

25 mV RMS

75%

105-250 VAC

27.6 VDC

+/- 400mV

2.5 Amps

3.0 Amps

4.0 Amps

1.00%

2.00%

35 mV RMS

75%

ICT22012-6

ICT22024-3

ICT12012-15

 (1)(2)

ICT12012-20

 (1)(2)

ICT12012-30

 (1)(2)

ICT12024-10

 (1)(2)

ICT12024-15

 (1)(2)

ICT12048-5

ICT22012-15

 (1)(3)

ICT22012-20

 (1)(3)

ICT22012-30

 (1)(3)

ICT22024-10

 (3)

ICT22024-15

 (3)

ICT22048-5

 (3)

90-130 VAC

13.8 VDC

+/- 150 mV

13.0 Amps

15.0 Amps

15.5 Amps

0.20%

0.80%

20 mV RMS

85%

90-130 VAC

13.8 VDC

+/- 150 mV

17.0 Amps

20.0 Amps

20.5 Amps

0.20%

0.85%

20 mV RMS

85%

90-130 VAC

13.8 VDC

+/- 150 mV

25.0 Amps

30.0 Amps

31.0 Amps

0.20%

0.85%

20 mV RMS

85%

90-130 VAC

27.6 VDC

+/- 150 mV

8.0 Amps

10.0 Amps

10.5 Amps

0.20%

0.75%

20 mV RMS

85%

90-130 VAC

27.6 VDC

+/- 150 mV

13.0 Amps

15.0 Amps

15.5 Amps

0.20%

0.75%

20 mV RMS

85%

90-130 VAC

48.0 VDC

+/- 150 mV

4.0 Amps

5.0 Amps

5.5 Amps

0.50%

1.00%

40 mV RMS

80%

90-130/

180-265 VAC

13.8 VDC

+/- 150 mV

13.0 Amps

15.0 Amps

15.5 Amps

0.20%

0.80%

20 mV RMS

85%

90-130/

180-265 VAC

13.8 VDC

+/- 150 mV

17.0 Amps

20.0 Amps

20.5 Amps

0.20%

0.85%

20 mV RMS

85%

90-130/

180-265 VAC

13.8 VDC

+/- 150 mV

25.0 Amps

30.0 Amps

31.0 Amps

0.20%

0.85%

25 mV RMS

85%

90-130/

180-265 VAC

27.6 VDC

+/- 150 mV

8.0 Amps

10.0 Amps

10.5 Amps

0.20%

0.75%

20 mV RMS

85%

90-130/

180-265 VAC

27.6 VDC

+/- 150 mV

13.0 Amps

15.0 Amps

15.5 Amps

0.20%

0.75%

20 mV RMS

85%

90-130/

180-265 VAC

48.0 VDC

+/- 150 mV

4.0 Amps

5.0 Amps

5.5 Amps

0.50%

1.00%

40 mV RMS

80%

A

 - Standard 7.1" Width

AG

 - 6.4" Width

AX 

- 5.6" Width

AM 

- with LCD Meter

AR

 - mounted on 19" Rackmount

ARM

 - with LCD Meter and Rackmount

(1)

 CSA C22.2 No 107.1, UL 1012 Approved

(2)

 

FCC class B Compliant

(3)

 

Switchable between 120 & 220 VAC Input - Internal Jumper

10 - 100 watts

100 - 200 watts

200 - 500 watts

ICT  Ltd.  warrants  to  the  original  consumer  purchaser  that  this 

product  shall  be  in  good  working  order,  free  from  defects  in 

materials and workmanship, for a period of one (1) year from the 

date of purchase. Should failure occur during the above stated time 

period, then ICT will, at its option, repair or replace this product at 

no additional charge except as set forth below. All parts, whether 

for repair or replacement, will be furnished on an exchange basis. 

All  exchange  pieces  become  the  property  of  ICT.  This  limited 

warranty shall not apply if the ICT product has been damaged by 

unreasonable  use,  accident,  negligence,  disaster,  service,  or 

modification by anyone other than the ICT factory.

Limited  warranty  service  is  obtained  by  delivering  the  product 

during  the  above  stated  one  (1)  year  warranty  period  to  an 

authorized ICT dealer or ICT factory and providing proof of purchase 

date. If this product is delivered by mail, you will insure the product 

or  assume  risk  of  loss  or  damage  in  transit,  and  prepay  shipping 

charges to the factory.

Every reasonable effort has been made to ensure that ICT product 

manuals and promotional materials accurately describe ICT product 

specifications and capabilities at the time of publication. However, 

because  of  ongoing  improvements  and  updating  of  ICT  products, 

ICT  cannot  guarantee  the  accuracy  of  printed  materials  after  the 

date  of  publication  and  disclaims  liability  for  changes,  errors  or 

omissions.

If this ICT product is not in good working order, as outlined in the 

above warranty, your sole remedy shall be repair or replacement as 

provided  above.  In  no  event  will  ICT  be  liable  for  any  damages 

resulting  from  the  use  of  or  the  inability  to  use  the  ICT  product, 

even  if  an  ICT  employee  or  an  authorized  ICT  dealer  has  been 

advised of the possibility of such damages, or for any claim by any 

other party.

ICT  reserves  the  right  to  make  changes  without  further  notice  to 

any  products  or  documentation  for  improvement  of  reliability, 

function, or design.

ICT  Ltd.  does  not  recommend  use  of  its  products  in  life  support 

applications  wherein  a  failure  or  malfunction  of  the  product  may 

directly  or  indirectly  threaten  life  or  cause  injury.  The  user  of  ICT 

products,  which  are  to  be  used  in  life  support  applications  as 

described above, assumes all risks of such use and indemnifies ICT 

against all damages.

This  device  complies  with  Part  15  of  the  FCC  Rules.  Operation  is 

subject to the following 2 conditions:

  1. This device may not cause harmful interference, and

  2. This device must accept any interference received, including                                                                                                                                                                                     

any interference that may cause undesired operation.

LIMITED WARRANTY

INNOVATIVE CIRCUIT TECHNOLOGY LTD.

26921 GLOUCESTER WAY     LANGLEY, BRITISH COLUMBIA, CANADA     V4W 3Y3

T

 604.856.6303     

F

 604.856.6365     

www.ict-power.com

NOTES

The  ICT  Comm  Series  can  be  used  in  parallel  or  series 

configurations. Please contact ICT for further information.

Most  ICT  Comm  series  products  are  available  in  various 

widths   (A  =  7.11",  AG  =  6.4",  AX  =  5.6")  and  can  be 

assembled  with  a  wide  variety  of  ICT  base  station  covers. 

120/220 Volt or 220 Volt input models are available, as well as 

12, 24, and 48 V output models. Options available also include 

an  LCD  meter  for  current  and  voltage  display,  and  a  19" 

rackmount configuration. Wallmount brackets are available for 

permanent installation. (part #ICT-WMB)

The  ICT  Comm  Series  can  also  be  used  to  charge  a  battery 

while powering an accessory without any modification. Please 

contact ICT for design note (DN-101 Battery backup).

The  ICT  Charger  Series  is  also  available,  which  offer  a 

complete  microprocessor  controlled  battery  backup  system. 

They  feature  fast  and  efficient  3  stage  battery  charging,  as 

well as full protection for both the battery and the charger.

Do not block side or bottom vent slots.

Do not place unit on or near sources of heat/moisture.

Incorrect wiring may result in serious damage to both power 

supply and equipment wired to power supply.

Unit service should be done by ICT.

SETUP

ICT COMM SERIES

WARNING

The ICT Comm Series switching power supplies deliver continuous 

trouble-free  operation  and  incorporate  extra  filtering,  providing  a 

virtually  noise-free  environment  for  a  wide  range  of 

communications equipment and 12V accessories. 

These instructions should be read before using the product and it 

should be saved for future reference.

Plug the enclosed power cord into the input plug on the back 

of the unit. Plug the other end into the AC outlet.

Connect equipment to terminal block at the rear of the unit.

Note: Keep the hook-up leads to the load as short as possible 

to avoid excess radiated noise.

To turn on power supply, press top of front panel switch.

AX

AG

A

AX

AG

A

CONNECTIONS

10 - 100 watts

100 - 200 watts

200 - 500 watts

SIGNED OFF BY:

Reviews: