Tunnel Master® wbc Installation Guide
Page 23
Main Inputs Wiring
Wiring is to be done on the main CPU board.
GATE SWITCH/PHOTO-EYE
EXTERNAL VOLTAGE-24VAC
TIRE SWITCH
EXTERNAL VOLTAGE-24VAC
ROLLER LOCATOR
SWITCH
EXTERNAL VOLTAGE-24VAC
REMOTE ROLLER/ROLLER CALL
SWITCH
EXTERNAL VOLTAGE-24VAC
ENTRANCE MANAGEMENT/FLOOR
SWITCH
EXTERNAL VOLTAGE-24VAC
ANTI-COLLISION PAD
AMPLIFIER
EXTERNAL VOLTAGE-24VAC
COM
COM
COM
COM
COM
COM
N/O
N/O
N/C
N/O
N/O
N/O
EXTERNAL VOLTAGE
JUMPER POSITION
DRY CONTACT JUMPER
POSITION
PRE-ASSIGNED
FUNCTION INPUTS
ICS RECOMMENDS 18 / 2 SHIELDED CABLE
PROVIDED BY SITE
GATE
TIRE SWITCH
ROLLER LOCATOR
REMOTE ROLLER
ENTRANCE MANAGEMENT
ANTI-COLLISION
JUMPERS SET TO
EXTERNAL VOLTAGE
DEVICES LOCATED IN THE
CARWASH TUNNEL
Figure 17. Main Inputs Wiring
GENERAL NOTE: ICS highly recommends using shielded cable for all input wiring. Terminate the shield
drain on the ground lug provided in the controller. Jumpers for each input must be set to external
voltage 24 V AC.
NOTE 1: Optimally, the roller locator switch should be wired normally closed to the ICS controller.
Wiring the roller locator switch normally open is acceptable but will mean waiting longer for the roller
to fire.