Tunnel Master® wbc Installation Guide
Page 22
Tunnel Master® wbc Installation Guide
Page 22
Pulse Switch Wiring
Wiring is to be done on the main CPU board.
2-WIRE
PULSE
SWITCH
3-WIRE
SINKING
PULSE SWITCH
3-WIRE
SOURCING
PULSE SWITCH
NO
COM
0V
SIGNAL
+VOLT
0V
SIGNAL
+VOLT
SOURCE
0V
+V
SINK
SOURCE
SOURCE
SINK
SINK
+V
+V
0V
0V
SINKING JUMPER
CONFIGURATION
SOURCING JUMPER
CONFIGURATION
ICS HIGHLY RECOMMENDS
USING 18 / 2 SHIELDED CABLE
ICS HIGHLY RECOMMENDS
USING 18 /
3
SHIELDED CABLE
ICS HIGHLY RECOMMENDS
USING 18 /
3
SHIELDED CABLE
BLUE WIRE
BLACK WIRE
BROWN WIRE
BLUE WIRE
BLACK WIRE
BROWN WIRE
WIRING FOR THE CONVEYOR
PROXIMITY SWITCH IS DONE
ON THE CPU BOARD
ENSURE THAT THE
JUMPER IS SET FOR
"SINKING"
ENSURE THAT THE
JUMPER IS SET FOR
"SINKING"
ENSURE THAT THE
JUMPER IS SET FOR
"SOURCING"
BELOW ARE EXAMPLES OF PROXIMITY SWITCH WIRING. PLEASE
CONFIRM THE TYPE OF WIRING REQUIRED PRIOR TO ANY WIRE
TERMINATION
Figure 16. Pulse Switch Wiring