Page 1: ...Model AOB8 12 AOB16 12 Product Manual MANUAL NUMBER 00650 134 4C...

Page 2: ...ual in our online Support Library Thank you The information in this document is provided for reference only ICS Advent does not assume any liability arising from the application or use of the informat...

Page 3: ...Page iv This page intentionally left blank...

Page 4: ...ts which are not in an as new and re saleable condition are not eligible for credit return and will be returned to the customer Limited Warranty Effective April 1 1998 all products carry a 2 year limi...

Page 5: ...made by various manufacturers in performing warranty repairs and building replacement products If ICS Advent repairs or replaces a product its warranty term is not extended ICSAdvent will normally re...

Page 6: ...Cautions and Warnings are accented with triangular symbols The exclamation symbol is used in all cautions and warnings to help alert you to the important instructions The lightning flash symbol is us...

Page 7: ...Page viii This page intentionally left blank...

Page 8: ...Outputs Update 6 Chapter 4 Address Selection 7 Chapter 5 Programming 9 Chapter 6 Data Format 13 Chapter 7 Software 15 Chapter 8 Calibration 17 Chapter 9 Connector Pin Assignments 19 Chapter 10 Specif...

Page 9: ...Page x This page intentionally left blank...

Page 10: ...disk To do this perform the following 1 Place the master diskette into a floppy drive 2 Change the active drive to the drive that has the master diskette installed For example if the diskette is the A...

Page 11: ...bles tighten screws 9 Replace the computer cover and apply power How to remain CE Compliant This device complies with CE Directives 72 23 EEC and EMC 89 336 EEC CE compliance is based on the interacti...

Page 12: ...p the AOBx 12 contain automatic circuits that set D A outputs to less than 15 of span at system power on Upon power up the DAC reference voltage is set to a low voltage and the card is set in the Simu...

Page 13: ...INTERFACE ADDRESS SELECT SWITCH OUTER DATA REGISTER INNER DATA REGISTER INNER DATA REGISTER 12 BIT DAC 15 12 BIT DAC 0 RANGE SELECT DISABLE OUTPUT SWITCH VREF 12VDC VREF VREF to all DACs GND RESET CO...

Page 14: ...e Range S1 S2 S3 0 to 2 5V OFF OFF ON 0 to 5V OFF OFF OFF 0 to 10V OFF ON OFF 2 5V to 2 5V ON OFF ON 5V to 5V ON OFF OFF 10V to 10V ON ON OFF Analog Outputs Update Analog outputs are updated under pro...

Page 15: ...Manual Number 00650 134 4 Page 6 AOB8 12 AOB16 12 Manual Figure 3 1 Option Selection Map...

Page 16: ...rogram FINDBASE provided on dis kette will assist you in selecting a base address that will avoid this conflict Hex Range Usage 000 0FF Internal System Not Usable 1F0 1FF AT Hard Disk 200 207 Game Con...

Page 17: ...binary form Then for each 1 of binary address set the corresponding DIP switch to OFF and for each 0 of binary address set the corresponding switch to ON Here s an example showing how to program the...

Page 18: ...sing a Clear Restrict Output Voltage command Simultaneous Update Mode is the power up or default mode of operation for the DAC card When a value is written to a DAC address the output does not change...

Page 19: ...Simultaneous Mode Base 11 DAC 5 High Byte Base 12 DAC 6 Low Byte Base 13 DAC 6 High Byte Base 14 DAC 7 Low Byte Restrict Output Voltage Limits outputs to 15 of full scale range Base 15 DAC 7 High Byte...

Page 20: ...Manual Number 00650 134 4 Page 11 BIT D7 D6 D5 D4 D3 D2 D1 D0 Low Byte B7 B6 B5 B4 B3 B2 B1 B0 High Byte x x x x B11 B10 B9 B8...

Page 21: ...Manual Number 00650 134 4 Page 12 AOB8 12 AOB16 12 Manual This page intentionally left blank...

Page 22: ...true binary form 0000 0000 0000 0000 ZERO 1000 0000 0000 0000 1 2 SCALE 1111 1111 1111 1111 FULL SCALE l MSB or B11 B0 or LSB For BIPOLAR ranges For Bipolar ranges data are in offset binary form 0000...

Page 23: ...Manual Number 00650 134 4 Page 14 AOB8 12 AOB16 12 Manual This page intentionally left blank...

Page 24: ...routine are found on the sample disk along with examples in other languages VisualBASIC Utility Driver Extensions to the VisualBASIC language are now provided on the diskette provided with your card...

Page 25: ...Declaration function Poke byval segment as integer byval offset as integer byval value as integer as integer Note that in all of the above functions an inherent limitation of BASIC in general and Visu...

Page 26: ...nnel c Check the 5V Reference Voltage d Adjust Unipolar zero on each channel e Adjust Unipolar range of each channel f Adjust Bipolar negative full scale of each channel g Check Bipolar zero of each c...

Page 27: ...Manual Number 00650 134 4 Page 18 AOB8 12 AOB16 12 Manual This page intentionally left blank...

Page 28: ...n r u t e R 1 2 D N G n r u t e R d n u o r G g o l a n A n r u t e R 2 2 D N G n r u t e R d n u o r G g o l a n A n r u t e R 3 2 D N G n r u t e R d n u o r G g o l a n A n r u t e R 4 2 D N G n r...

Page 29: ...Manual Number 00650 134 4 Page 20 AOB8 12 AOB16 12 Manual Note The figure below shows how pins are numbered on D type connectors...

Page 30: ...ting temperature range SettlingTime 8 usec to one LSB for full scale step input Linearity LSB integral non linearity over rated temperature range GainStability 15 ppm C OutputDriveCapability 5mAmaximu...

Page 31: ...ternal Win32IRQ dll index 1 function DetectIRQ Boolean stdcall external Win32IRQ dll index 2 function SendEOI Boolean stdcall external Win32IRQ dll index 3 In C the library file Win32IRQ lib must firs...

Page 32: ...ogram needs to continue running while waithing for DetectIRQ a separate thread should be spawned from which to call DetectIRQ The return result is TRUE if an IRQ was successfully detected on the given...

Page 33: ...4 3 1995RadiatedRFFieldImmunity EN61000 4 4 1995EFTImmunityforACandI OLines EN 60950 1992 Safety of InformationTechnology Equipment Thetechnicaldocumentationrequiredtodemonstratethisproductmeetsthereq...