Manual Number: 00650-009-28
Page 1-4
WDT1000-P Manual
Specifications
Watchdog Timer
Time-out
Software selectable from 5 mSec to 291 Sec in 5
mSec increments.
Clock
255 Hz, crystal controlled.
Address
Continuously mappable within 000 to 3FF hex I/O
range.
Temperature Alarm
Level
Factory preset at 50 ° C ±2 ° Adjustable.
Interrupt Output
Jumper selectable.
Alternate Output
Can be read at base a 4.
Serial Interface
Multipoint
Compatible with RS422 and RS485 specifications.
Common Mode Voltage
-7V to +12V CMV will not affect operation.
Driver Output Capability
60 mA maximum.
Receiver Input Sensitivity Can detect signals as small as ±200 mV.
Baud Rate
50 to 9600 baud. (to 56,000 baud optional).
Crystal oscillator on board.
Address
Continuously mappable within I/O address range000- 3FF hex.
Environmental
Operating Temperature Range
0 to +60 ° C.
Storage Temperature Range
-50 ° to +120 ° C.
Humidity
10% to 90% RH, non-condensing.
Power Required:
+5 VDC at 420 mA typical, 500 mA maximum.
Size
13.3 inches long. Requires full size slot.
(00201.wmf)
Summary of Contents for WDT1000-P
Page 1: ...Model WDT1000 P Product Manual MANUAL NUMBER 00650 009 28C...
Page 2: ...Page ii...
Page 4: ...Page iv This page intentionally left blank...
Page 14: ...Manual Number 00650 009 28 Page 1 6 WDT1000 P Manual This page intentionally left blank...
Page 20: ...Manual Number 00650 009 28 Page 3 4 WDT1000 P Manual This page intentionally left blank...
Page 26: ...Manual Number 00650 009 28 Page 5 6 WDT1000 P Manual This paage intentionally left blank...
Page 28: ...Manual Number 00650 009 28 Page A 2 WDT1000 P Manual This page intentionally left blank...
Page 32: ......
Page 34: ......