You can set 6 time periods per day.
Step 3
Click
Save
.
5.1.1.3.2
Setting Snapshot Linkage
When enabled, the IPC will take a snapshot when the event is triggered.
Figure 5-9 Snapshot linkage
5.1.1.4
Relay-out Linkage
When enabled, the IPC will take a trigger the alarm relay-out device when the event is triggered.
The
Alarm Delay
value determines the amount of time the alarm out will continue to trigger after
the event has ended.
Figure 5-10 Relay-out linkage
5.1.1.5
Email Linkage
When enabled, the IPC will send an email to users when the event is triggered..
This will only function if the SMTP section has been configured. For details, see "4.6.5 SMTP (Email)".
Figure 5-11 Email linkage
5.1.1.6
PTZ Linkage
When enabled, the PTZ will link an operation when the event is triggered.. For example, the PTZ
will rotate to to a specified preset.
Figure 5-12 PTZ linkage
5.1.1.7
Warning Light Linkage
When enabled, the IPC will automatically enable a warning light (If it comes equipped
with one). Set
Mode
,
Flicker Frequency
,
Duration
, and
Period
.
●
Mode
: The display mode of the warning light when an alarm is triggered. It includes
Normally
on
and
Flicker
. When setting
Flicker
as the mode, you need to set the flicker frequency.