PEX-P32C32/PISO-P32C32U Series Quick Start Guide
ICP DAS CO., LTD.
5
WebSite: http:// www.icpdas.com.tw E-Mail: [email protected] , [email protected]
Prepare for device:
DN-37 (optional) wiring terminal board.
Exterior power supply device. For example: DP-665 (optional)
Self-test wiring as follows:
1.
Use the DN-37 to connect the CON1 on board.
2.
Keep set the J1 and JP2 jumper to
External Power (Page 2)
.
3.
Connect the DI(0-15) with DO(0-15).
(DI0 with DO0 … DI15 with DO15)
PEX-P32C32 and PISO-P32C32U External Power Wiring:
4.
Power Supply (+24 V)
connect to
ECOM0 (Pin18)
.
Power Supply (+24 V)
connect to
Ext.PWR0 (Pin37)
.
Power Supply GND
connect to
IGND0 (Pin19)
.
Power Supply GND
connect to
Ext.GND0 (Pin1 and Pin20)
.
PISO-P32C32U-5V External Power Wiring:
4.
Power Supply (+5 V)
connect to
ECOM0 (Pin18)
.
Power Supply (+5 V)
connect to
Ext.PWR0 (Pin37)
.
Power Supply GND
connect to
IGND0 (Pin19)
.
Power Supply GND
connect to
Ext.GND0 (Pin1 and Pin20)
.
Self-Test
The PEX-P32C32/PISO-P32C32U suggests input voltage range as follow:
Logic high: +9 ~ +24 V
; Logic Low: 0 ~ 1V.
(Higher voltage over the limitation will cause the hardware damage.)
The PISO-P32C32U-5V suggests input voltage range as follow:
Logic high: +5 ~ +12 V
; Logic Low: 0 ~ 1V.
(Higher voltage over the limitation will cause the hardware damage.)