SERVICE AND TECHNICAL SUPPORT MANUAL

Gas Furnace: N9MSE

Specifications  subject to change without notice.

440 04 4402 03

23

Figure 16

Troubleshooting  

 Flow Chart

Is

 LE

D s

tat

us lig

ht 

ON s

o

lid, 

alt

e

rn

atel

flashi

ng bri

ght

-d

im

-b

rig

h

t-

dim

 lik

e a

 

h

ea

rtb

e

a

t, o

r fl

ashi

ng 

ON a

n

d

 O

F

F

?

  

 

Is

 th

er

e 2

4

V

 at

 2

4

V

A

C

 a

nd C

O

M? 

 

Is

 th

er

e 1

15V

 at 

L1 

an

NE

UT

RA

L?

  

Is

 th

e 2

4

V

 f

u

se 

op

en

?

  

Is

 do

or

 s

w

itc

h

 clo

s

ed

 

Rep

la

ce t

ra

n

sf

orm

e

r.

  

Rep

la

ce do

or 

s

w

it

ch

 

Is

 th

er

e 1

1

5V

 goi

ng t

o

 s

w

it

ch

 

Cl

ose 

the

 d

oor

 s

w

itc

h

 

Is

 circ

uit 

bre

a

k

e

r cl

ose

d

 

Che

ck

 fo

r co

nti

n

uit

y

 i

n

 w

ir

e

 fr

om

 ci

rc

ui

b

rea

ke

r to

 fu

rn

a

c

e.

  

Cl

ose 

circ

uit b

re

a

k

e

r a

n

go

 ba

ck

 to 

ST

ART

.  

Is

 LE

D s

tat

us li

g

h

alte

rn

atel

y

 fla

s

hin

g

 

brig

ht

-d

im

-b

rig

h

t-

dim

 lik

e a h

e

a

rtb

eat

 

Dete

rm

ine

 s

ta

tus c

o

d

e

.  T

h

e st

atu

s

 co

d

e

 

is a 

si

ngle

 or

 t

w

o

 di

git

 n

u

m

b

e

w

it

h

 t

he 

fir

s

num

b

e

det

erm

in

ed b

y

 t

he num

b

e

r of 

shor

t fl

ash

e

s a

nd 

th

e se

con

d

 num

b

e

afte

the plus (+)

 sig

n

the num

b

e

of l

o

ng 

flash

e

s.

 

T

o

 r

e

c

a

ll a

 sta

tu

s

 cod

e

: B

riefl

y

 (2

 

 3 

seco

nds

) c

onn

ect 

th

e

 T

EST

/T

W

IN te

rm

ina

to

 t

h

“C

” 

th

e

rm

o

st

at t

e

rm

in

al 

w

it

h

 a

 j

u

m

p

er

 

wi

re

 t

o

 b

egi

n st

atu

s

 co

de

 re

cov

e

ry

 an

com

p

o

nen

t t

e

st. 

If a

 p

revio

us s

ta

tus c

o

de is 

pres

en

t, t

he c

o

d

e

 w

ill

 re

pea

t 4

 tim

e

s t

h

en 

go 

on t

o

 c

o

m

p

o

nen

t t

e

st. 

If n

o

 pre

v

iou

s

 

cod

e

 is p

re

s

en

t, a

 co

m

p

on

ent

 tes

w

ill 

begi

n w

it

h

o

u

fl

ashi

ng an

y

 sta

tus cod

e

s

 

C

o

mpon

en

t T

e

s

S

e

qu

enc

e

: Ga

s

 va

lv

and

 h

u

m

idi

fier

 w

ill n

o

be t

u

rn

e

d

 on

In

d

u

ce

m

o

to

r w

ill sta

rt 

a

n

d

 r

e

m

a

in

 on until 

the 

en

d o

f th

e bl

o

w

e

r t

e

st,

 th

en 

off.

 T

he

 

foll

o

w

ing c

o

m

p

o

n

e

n

ts 

ar

e o

n

 f

o

10 

 15

 

seco

nds 

ea

ch i

n

divi

duall

y

: h

o

t s

u

rf

a

c

ign

ite

r, 

blo

wer spe

e

ds

: FA

N

 (if

 pr

es

ent

),

 

HE

AT

, COOL

W

a

s there 

a p

revi

ous 

stat

us c

o

d

e

 

Go t

o

 s

e

ctio

n b

e

lo

w fo

r t

he fl

ash

ed 

sta

tus

 

cod

e

.  

Doe

th

e

 co

ntr

o

l r

e

sp

on

d t

o

 W

, Y

1

Y

/Y2, 

and

 G 

(24V

) t

h

e

rm

o

sta

t sig

nals

?

 

Run s

y

stem

 t

h

ro

u

g

a

 h

eat

, o

r c

ooli

n

c

y

cle t

o

 c

heck

 op

er

atio

n.  S

tat

us c

o

d

e

s

 

are

 er

ase

d

 afte

r 7

2

 hou

rs.

 

Is

 2

4

V

 p

res

ent 

at 

W

, Y

1

Y/

Y

2

 or

 G 

th

e

rm

o

sta

t te

rm

ina

ls

 o

n

 th

e f

u

rnac

cont

rol

?

 

Check

 ro

om

 th

erm

o

s

tat 

or

 

inter

co

nne

ctin

g ca

ble

Di

scon

nec

t all

 the

 th

erm

o

s

tat 

wi

re

s fr

o

m

 

the fur

n

ac

c

ont

rol.

 

Does 

the

 p

robl

em

 r

epe

at 

whe

n u

s

ing

 a 

jum

per

 w

ire

?

 

Repla

ce f

u

rnac

e c

ont

rol.

 

T

he th

erm

o

s

tat

 is n

o

t c

o

m

pati

b

le

 w

ith 

th

fur

nac

e co

ntr

o

l. 

 E

ithe

r i

n

stall

 a 

ball

a

st 

resist

o

r,

 co

nn

ect t

h

e

 

C

 fu

rn

ace

 co

ntr

o

th

e

rm

o

sta

t te

rm

ina

to

 th

e

 th

er

m

o

s

ta

t,

 o

repl

ace

 th

e t

herm

o

stat

YE

S

 

NO 

YE

S

 

YE

S

 

YE

S

 

YE

S

 

YE

S

 

YE

S

 

YE

S

 

STAR

T

 

YE

S

 

YE

S

 

NO 

NO 

NO 

NO 

NO 

NO 

NO 

NO 

YE

S

 

NO 

NO 

Troubles

h

ooting Guide

 

Repla

ce f

u

rnac

e c

ont

rol.

  

YE

S

 

Insp

ect 

s

e

c

ond

ar

y

 volt

ag

(24V

) w

iri

ng,

 

includi

ng 

th

erm

o

st

at l

e

a

d

s f

o

r s

h

o

rt 

circuit

Rep

la

ce f

u

s

e

 

NO 

Is

 L

E

D s

ta

tus lig

ht 

ON s

o

lid?

  

NO 

YE

S

 

T

he co

ntr

o

l is l

o

ck

ed 

out

 an

w

ill

 aut

o

-

rese

a

fte

1 ho

ur.

  

L

o

ck

out coul

d be du

to 

a

n

y

 of 

the foll

o

w

in

g

Flam

e s

e

n

s

e ci

rcui

t fail

ur

e.

 

G

a

s

 va

lv

e r

e

lay

 st

u

c

k op

e

n

- S

o

ft

w

a

re 

che

c

k

 err

o

r.

 

Rese

t p

o

wer

 to

 cle

a

r l

o

ck

out. 

 Re

plac

cont

rol if

 co

de 

re

pe

ats.

 

Summary of Contents for N9MSE0401712A

Page 1: ...or pictures or product labels The signal word WARNING is used throughout this manual in the following manner Safety alert symbol When you see this symbol on the unit and in instructions or manuals be...

Page 2: ...eath WARNING signifies hazards which could result in personal injury or death CAUTION is used to identify unsafe practices which may result in minor personal injury or product and property damage NOTE...

Page 3: ...am of Furnace Drip Leg Gas Valve turned ON Type of Gas Natural Propane Filter Type and Size Check in box the Blower OFF Delay Jumper Heating Position for Fan Time OFF Setting 1 and 2 2 and 3 3 and 4 5...

Page 4: ...is energized whenever blower operates HUM 24vac terminal is only energized the draft inducer is energized in heating Prime Condensate Trap with Water CARBON MONOXIDE POISONING HAZARD Failure to follo...

Page 5: ...ce has the correct orifice installed At higher altitudes or different gas heat contents it may be necessary to change the factory orifice to a different orifice Tables have been provided in the furnac...

Page 6: ...rewdriver counterclockwise out to decrease input rate or clockwise in to increase input rate NOTICE DO NOT set low heat manifold pressure less than 2 8 in w c 697 Pa or more than 3 8 in w c 947 Pa for...

Page 7: ...24 VAC CONNECTIONS P2 HOT SURFACE IGNITOR HSI INDUCER MOTOR IND CONNECTOR 115 VAC L1 LINE VOLTAGE CONNECTION SPARE1 COM BLUE 115 VAC L2 NEUTRAL CONNECTIONS 24 V THERMOSTAT TERMINALS HUMIDIFIER TERMINA...

Page 8: ...300 21 171 343 857 62 58 116 290 22 164 327 818 64 56 112 281 23 157 313 783 66 54 109 273 24 150 300 750 68 53 106 265 25 144 288 720 70 51 103 257 26 138 277 692 72 50 100 250 27 133 267 667 74 48 9...

Page 9: ...42 3 4 42 3 5 42 3 6 3001 800 43 3 8 42 3 2 42 3 3 42 3 4 915 825 43 3 6 43 3 7 43 3 8 42 3 2 850 44 3 8 43 3 5 43 3 6 43 3 7 875 44 3 6 44 3 7 43 3 4 43 3 5 4000 900 44 3 4 44 3 5 44 3 7 44 3 8 1219...

Page 10: ...ding Leaving blower door off will result in incorrect temperature measurements due to possible changes in duct static pressure and airflow FURNACE DAMAGE HAZARD Failure to follow this caution may resu...

Page 11: ...minals R and W The thermostat anticipator should NOT be in the circuit while measuring current 1 Remove thermostat from sub base or from wall 2 Connect an amp meter across the R and W sub base termina...

Page 12: ...85 750 715 665 605 0802120 BOTTOM or TWO SIDES 3 4 Black 2360 2250 2160 2065 1970 1880 1785 1685 1580 1455 Yellow 2100 2030 1960 1885 1805 1720 1635 1545 1440 1305 Orange 1840 1810 1765 1725 1665 1590...

Page 13: ...nominal break point of each switch is shown on the label below the reference location in inches of water column W C The maximum and minimum break point of the switch is 0 05 inches of water column fro...

Page 14: ...D 6 A component test sequence will follow 7 Reinstall the Main Control door Component Self Test NOTE The furnace control component test allows all components to run for a short time except the gas val...

Page 15: ...rvice as necessary 4 Inspect burner compartment before each heating season for rust corrosion soot or excessive dust If necessary have furnace and burner serviced by a qualified service agency 5 Inspe...

Page 16: ...t on blower wheel remove wheel from the blower housing and wash it with an appropriate degreaser To remove wheel a Mark blower wheel location on shaft before disassembly to ensure proper reassembly b...

Page 17: ...old or damaging the mounting to the burner assembly ELECTRICAL SHOCK AND FIRE HAZARD Failure to follow this warning could result in personal injury death and or property damage Turn off the gas and el...

Page 18: ...ontrol door when complete Servicing Hot Surface Igniter The igniter does NOT require annual inspection Check igniter resistance before removal Refer to Figure 9 Figure 10 and Figure 11 1 Turn off gas...

Page 19: ...r drain extension elbow to the condensate trap 7 Connect the leads of the condensate heat pad if used 8 Connect external drain piping to the condensate drain elbow or drain extension pipe 9 Turn gas o...

Page 20: ...ratures may be 32_ F 0_ C or lower freeze protection measures must be taken to prevent property or product damage CAUTION Since the furnace uses a condensing heat exchanger some water will accumulate...

Page 21: ...SERVICE AND TECHNICAL SUPPORT MANUAL Gas Furnace N9MSE Specifications subject to change without notice 440 04 4402 03 21 Figure 14 Service Label 338310 2 Rev F...

Page 22: ...SERVICE AND TECHNICAL SUPPORT MANUAL Gas Furnace N9MSE Specifications subject to change without notice 22 440 04 4402 03 Figure 15 Wiring Diagram 339241 2 Rev A...

Page 23: ...nce Gas valve and humidifier will not be turned on Inducer motor will start and remain on until the end of the blower test then off The following components are on for 10 15 seconds each individually...

Page 24: ...nt test Does the igniter glow orange white by the end of the 15 second warm up period Unplug igniter harness from control and repeat component test Check for 115V between connector P2 HSI and NEUTRAL...

Page 25: ...econds after the gas valve GV is energized Simultaneously the electronic air cleaner terminal EAC is energized and remains energized as long as the blower motor BLWM is energized f Heat Off Delay When...

Page 26: ...ctor box Condensate trap Condensate trap elbow Gaskets WARNING FIRE EXPLOSION ELECTRICAL SHOCK AND CARBON MONOXIDE POISONING HAZARD Failure to follow this warning could result in dangerous operation p...

Page 27: ...ble Speed X ECM S Single stage T Two stage FEATURE B Base AFUE Efficiency E Extra AFUE Efficiency C Communicating D Dual Certified 2 pipe or 1 pipe R 2 pipe only S Single stage T Two stage N Standard...

Reviews: