NOVA-3710/3710SV Socket 370 Celeron
TM
& Pentium III
®
Multimedia & Dual VGA , Ethernet Embedded Board
78
Wrong Board In Slot
PLEASE RUN EISA CONFIGURATION UTILITY
The board ID does not match the ID stored in the EISA non-volatile memory.
NOTE: When this error appears, the system will boot in ISA
mode, which allows you to run the EISA Configuration
Utility.
FLOPPY DISK(S) fail (80)
→
Unable to reset floppy subsystem.
FLOPPY DISK(S) fail (40)
→
Floppy Type dismatch.
Hard Disk(s) fail (80)
→
HDD reset failed
Hard Disk(s) fail (40)
→
HDD controller diagnostics failed.
Hard Disk(s) fail (20)
→
HDD initialization error.
Hard Disk(s) fail (10)
→
Unable to recalibrate fixed disk.
Hard Disk(s) fail (08)
→
Sector Verify failed.
Keyboard is locked out - Unlock the key.
BIOS detect the keyboard is locked. P17 of keyboard controller is pulled
low.
Keyboard error or no keyboard present.
Cannot initialize the keyboard. Make sure the keyboard is attached
correctly and no keys are being pressed during the boot.
Manufacturing POST loop.
System will repeat POST procedure infinitely while the P15 of keyboard
controller is pull low. This is also used for M/B burn in test.
BIOS ROM checksum error - System halted.
The checksum of ROM address F0000H-FFFFFH is bad.
Summary of Contents for NOVA-3710