background image

 

ICP

 

DAS,

 

ZT

USB

 

Series

 

User

 

Manual,

 

Version

 

1.0

   

Page

 

1

 

 

Copyright

 

@

 

2013

 

by

 

ICP

 

DAS

 

Co.,

 

Ltd.

 

All

 

Rights

 

Reserved.

 

ZT-USB Series 

User  Manual 

Warranty

 

All products manufactured by ICP DAS are under warranty regarding 
defective materials for a period of one year, beginning from the date of 
delivery to the original purchaser. 

Warning

 

ICP DAS assumes no liability for any damage resulting from the use of 
this product. ICP DAS reserves the right to change this manual at any 
time without notice. The information furnished by ICP DAS is believed to 
be accurate and reliable. However, no responsibility is assumed by ICP 
DAS for its use, nor for any infringements of patents or other rights of 
third parties resulting from its use. 

Copyright

 

Copyright © 2013 by ICP DAS. All rights are reserved. 

Trademarks

 

Names are used for identification purpose only and may be registered 
trademarks of their respective companies. 

Technology

 

Support

 

If you have any problems, please feel free to contact us via 
email at 

[email protected]

 

 

Summary of Contents for ZT-USBC

Page 1: ...oduct ICP DAS reserves the right to change this manual at any time without notice The information furnished by ICP DAS is believed to be accurate and reliable However no responsibility is assumed by I...

Page 2: ...ont View 7 3 3 Dimensions Units mm 8 3 4 Block Diagram 9 4 Installing Driver and Utility 10 4 1 Installing the ZT USB Serial Port Driver 10 4 2 Inserting the ZT USB and installing Driver 13 4 3 Instal...

Page 3: ...please contact your local distributor for more information Save the shipping materials and cartons in case you want to ship the module in the future Documentation CD Napdos ZigBee ZT_Series document h...

Page 4: ...d control or high power transmitter receiver able to reach all of the devices Any ZigBee device can be tasked with running the network ZigBee is targeted at applications that require a low data rate l...

Page 5: ...re specification for a suite of high level communication protocols using small low power digital radios module which are fitted the ZigBee 2007 ZigBee Pro of ZigBee Alliance In the ZigBee network it i...

Page 6: ...nterface Connector Type A Plug Compatibility USB 1 1 and 2 0 standard USB Driver Windows 2000 XP Vista 7 8 Power Required Supply Voltage USB Socket Powered Power Consumption 0 3 W Max Mechanism Casing...

Page 7: ...r more details please see the section 6 troubleshooting 2 USB Type A Plug The port is used to configure ZT USB series communicate with other ZT 2000 modules and be powered via the USB socket 3 2 4 GHz...

Page 8: ...3 3 Dimensions Units mm Left Side View Front View Top View ICP DAS ZT USB Series User Manual Version 1 0 Page 8 Copyright 2013 by ICP DAS Co Ltd All Rights Reserved...

Page 9: ...3 4 Block Diagram ZigBee Module LED Display USB Type A Power Circuit ICP DAS ZT USB Series User Manual Version 1 0 Page 9 Copyright 2013 by ICP DAS Co Ltd All Rights Reserved...

Page 10: ...in the shipping package CD Napdos ZigBee ZT_Series driver 2 Right click the ZT USB_Series_Driver_Installer exe file and select the item that Run as adminstrator to install the driver for the ZT USB S...

Page 11: ...ing screen is displayed click the Next button to continue 6 If the following screen is displayed click the Always trust software from ICP DAS Co LTD and press Install button to continue W ICP DAS ZT U...

Page 12: ...click the Finish button to continue 8 When the following screen is displayed click the Finish button to completing the installation ICP DAS ZT USB Series User Manual Version 1 0 Page 12 Copyright 201...

Page 13: ...driver automatically and successfully 2 Right click on My Computer and select Properties Inserting the ZT USB and installing Drive USB ZT USB Series 3 Select Device Manager from the System Properties...

Page 14: ...OM LPT is failed to allocate the COM Port Number of ZT USB Series you should find USB Serial Port item below Other devices and right Click the Update Driver Software to update driver manually ICP DAS...

Page 15: ...iver software Option to continue 7 Browse to C ICPDAS ZT USB driver to locate the install tion file and click a Include subfolders and the Next button to begin the search ICP DAS ZT USB Series User Ma...

Page 16: ...lation NOTICE When the driver installation is complete unplug ZT USB Series 9 Device Manager and insert it in again Now you can find out the correct COM Port Number of ZT USB series in the ICP DAS ZT...

Page 17: ...2 Double click the ZT2000_Configuration_Utility_vxxx exe file to install the configuration tool for the ZT USB series 3 When the following screen is displayed you can click the Next button to install...

Page 18: ...k the Next button to c W ontinue When the following sc 5 reen is displayed click the Finish button to finalize the software installation ICP DAS ZT USB Series User Manual Version 1 0 Page 18 Copyright...

Page 19: ...k as other ZigBee module Valid values range from 0x0001 to 0xFFF7 for a ZigBee Router but is fixed to 0x0000 for a ZigBee Coordinator 3 RF Channel indicates the radio frequency channel and must be set...

Page 20: ...rate Data Format serial port settings are supported by ZT USB Series Item Specification Parity None Default Odd Even Data Bit 8 Stop Bit 1 Baud rate 2400 4800 9600 19200 38400 57600 76800 and 115200...

Page 21: ...f sending broadcast frame in order to prevent the network crashes Please fill in the number of ZT 2000 and ZT USBR slaves mple 6 Communication Speed The Interval Time of Sending B The d data i than 79...

Page 22: ...igBee Host sends DATA_01 via broadcasting frame Both of the ZigBee slave 0x0001 and 0x0002 will receive the DATA_01 Broadcasting type frame data will be sent to every ZigBee slaves in the same ZigBee...

Page 23: ...iguring ZigBee Setting Launch the ZT Configuration Utility and click the ZT Series button Click the Serial Port icon and then select the COM Port number After selecting the COM Port number a list of m...

Page 24: ...5200bps and RF parameters N 8 1 5 Once a connection is established select either the Default or the Wizard function from the settings mode page 4 5 Default Wizard 6 Whether you select either the Defau...

Page 25: ...t 2013 by ICP DAS Co Ltd All Rights Reserved 7 Setting Pan ID Node ID RF Channel For more details please see section 4 1 8 Baud Rate and Data Format 9 Once the module configuration has been completed...

Page 26: ...C and ZT USBR to the Host PC via the USB ports You may need to use two serial port tools to simulate the data transmission Method 2 Use the DCON Utility on the Host PC to search for ZT 2000 series I O...

Page 27: ...ommunication 1 ZT USB series are able to be integrated into SCADA easily If you choose ICP DAS ZT 2000 you can implement monitoring and controlling right away 2 ZT USB series are easy to deploy into h...

Page 28: ...e This file can be obtained using the procedure outlined below and should be attached to your email a Launch the ZT Configuration Utility and select Save Log icon to save the configuration of the ZT U...

Page 29: ...in ZigBee Network or It has Occupied ZigBee Router Slave Steady Lit The Signal is Strong ZigBe Red e Net LED Blinking 500 ms The Signal is Available Blinking 1s The Signal is Weak Blinking 2s The Sign...

Reviews: