background image

ZT

2570/ZT

2571

 

 

Quick

 

Start

 

1

 

What’s

 

in

 

the

 

shipping

 

package?

 

The package includes the following items: 

 

 

2

 

Preparations

 

for

 

devices

 

1.

 

Install ZT Configuration Utility (v1.0.0 or later)

 

CD: 

\

Napdos

\

ZigBee

\

ZT_Series

\

Utility 

http://ftp.icpdas.com/pub/cd/usbcd/napdos/zigbee/zt_series/utility

 

 

2.

 

Power Supply

+10 ~ +30V

DC

 

ZT

257x

 

Device

 

CD

 

ANT

124

05

 

Release

 

Note

 

CA

0915

 

(ZT

2570)

 

/

CA

0910N (ZT

2571)

GND

 

+Vs 

If any of these items are missing or damaged, please contact the local distributor 
for more information. Save the shipping materials and cartons in case you want to 
ship the module in the future. 

ICP

 

DAS,

 

ZT

2570/ZT

2571

 

Quick

 

Start,

 

Version

 

1.2

   

Page

 

1

 

Summary of Contents for ZT-2570

Page 1: ...tp ftp icpdas com pub cd usbcd napdos zigbee zt_series utility 2 Power Supply 10 30VDC ZT 257x Device CD ANT 124 05 Release Note CA 0915 ZT 2570 CA 0910N ZT 2571 GND Vs If any of these items are missi...

Page 2: ...ZigBee Coordinator 3 RF Channel indicates the radio frequency channel and must be set to the same channel if the module is in the same ZigBee network as other ZigBee modules Channel 0x00 0x01 0x0F Fre...

Page 3: ...427 CH 7 2440 CH 5 2432 CH 8 2445 CH 6 2437 CH 9 2450 CH 7 2442 CH A 2455 CH 8 2447 CH B 2460 CH 9 2452 CH C 2465 CH 10 2457 CH D 2470 CH 11 2462 CH E 2475 CH 12 2467 CH F 2480 CH 13 2472 CH 14 2484 R...

Page 4: ...s This parameter decides the broadcasting frame sending interval time to avoid the network overloading User only fills in the number of ZT 2000 slaves nearby the ZigBee Coordinator Example 79 Bytes 20...

Page 5: ...t the same time b Ethernet Either TCP Server or TCP Client is enabled and it allows working with RS 232 or RS 485 at the same time c Virtual COM Virtual COM driver needs to be installed in the desktop...

Page 6: ...t Data will be sent to all ZigBee slaves ZT 2571 Unicast Data will only be sent to the coordinator Eg1 When ZT 2550 ZigBee Host sends DATA_01 via broadcasting frame Both of the ZigBee slave 0x0001 and...

Page 7: ...icast frame Only the ZigBee Slave 0x0001 receives DATA_01 Unicast type frame data will be only sent to the specific ZigBee node Eg2 When ZigBee slave 0x0001 sends 0002DATA_02 via unicast frame Only th...

Page 8: ...network Eg2 When ZT 2570 receives data MTCP_CMD_02 from Ethernet ZT 2571 will convert protocol then output MRTU_CMD_01 to serial port ZT 2571 will output the data MTCP_CMD_01 directly to Ethernet Broa...

Page 9: ...RS 485 Ethernet ZBSET ZBRUN ZBINIT CA 0910N CA 0915 ZT 2570 ZT 2571 Windows Based PC F G D D GND VS RS 485 Converter Windows Based PC ZT 255x ZT 2570 ZB 2571 Windows Based PC 3 Enable the power It mea...

Page 10: ...eries 2 Single click either the Serial Port or Ethernet icon with the correct number of COM Port or IP Address that is used to select the communication interface 1 2 Serial Port Ethernet Double click...

Page 11: ...on 4 Once a connection is established select either the Default or the Wizard function from the settings mode page 5 Whether you select either the Default or the Wizard option for performing configura...

Page 12: ...iguration has been completed the message The Configuration was successful will be displayed Return the DIP switch to the ZBRUN position and reboot the ZT 255x device ICP DAS ZT 2570 ZT 2571 Quick Star...

Page 13: ...rve 1 First please confirm the desktop and ZT 257x is installed in the same network environment The default network setting of ZT 257x as below ZT 257x device IP 192 168 255 1 Mask 255 255 0 0 Gateway...

Page 14: ...P setting which is the same segment to the LAN of desktop Please also click the Set button to complete the configurations d After configuring the IP setting you may try to ping the device to see wheth...

Page 15: ...T 257x device http index htm 4 When the browser access correctly the web page will show all the configuration settings as below User may enter the new setting value to the correct filed if there are a...

Page 16: ...x configuration 6 When the configuration completed and successful it will show The system is updated with new configurations Please reload the web page to see whether the configuration is correct or n...

Page 17: ...se confirm the ZB Net LED indicator of ZigBee salves whether is steady lighted or not If the status of green LED indicator is steady lighted it means the connection has established and user can start...

Page 18: ...ny devices are found it means that the configuration is correct ZT 2570 RS 232 RS 485 ZT 2000 DCON Utility RS 232 RS 485 RS 232 RS 485 Serial Tool ZT 2570 ZT 2571 Serial Tool Download MiniOS Utility h...

Page 19: ...ols to simulate the data transmission Method 2 Use the EZ Data Logger as a TCP Client which is connected to the ZT 2570 on the Host PC to search for ZT 2000 series I O modules If there any devices are...

Page 20: ...ined using the procedure outlined below and should be attached to your email a Set the DIP switch of the ZT 257x device to the ZBSET position then reboot the device Launch the ZT Configuration Utility...

Page 21: ...ZigBee Router Slave Steady Lit Signal Strength Blinking 500 ms Signal Available Blinking 1s Signal Weak ZigBee Net Green LED Blinking 2s Signal Terrible or No ZigBee Network The status of ZigBee commu...