2.3.2.1. Installation for WinPAC-5000-CE7
The following procedure describes how to install the PenMount serial touch driver.
Note that
the default COM port for serial touch driver is COM4
.
Please use COM1 or COM2 to communicate with the touch panel. Please note the
position of TX and RX of COM port. About the pin assignment, please refer to the
user manual of the WinPAC-5000-CE7.
1.
Copy the driver from the CD-ROM to the WinPAC.
The
“PenMount_Serial_TOUCH_Vyyyymmdd(PM6000R).CAB” driver file can be
obtained from:
[name]
Driver path
TP-2070/TP-3080/TP-5120/
TPM-4100_TP-4100/TP-6150
/TP-7170
CD:\[name]\Driver\WinCE\V7.0\WP-5000-CE7 device
For example:
CD:\TP-6150 \Driver\WinCE\V7.0\WP-5000-CE7 device
Or go to the
“\System_Disk\External_device_driver\” folder on the
WinPAC.
2.
Double-click the
“
PenMount_Serial_TOUCH_Vyyyymmdd(PM6000R).CAB
” file.
Warning:
The WinPAC-5000-CE7 series
doesn
’t include a COM4, so
please refer to
“Changing the
COM Port
” in Sec.2.3.2.2 for
details of how to change the
COM Port to the specified COM
Port
.