background image

 

11 

 

2.5   LED Indicators 

There are three LED indicators to help users to judge the various conditions in the 
RMV-514. The description is as the following: 
(1)  EXT  (Red):  The  External  Power  LED  indicated  status  whether  the  power  is 

supplied or not. The description is as the following: 

 
 
 
 
 
(2)  GSM (Green): The modem LED can indicate the status of GSM module. 
 
 
 
 
 

 

(3)  STA (Orange): The system LED indicated whether the RMV-514 is normal of 

failed. 

 
 
 

The Power is active 

The Power is not active 

ON 

OFF 

GSM module normal 

GSM module failed 

Blinking (3 sec) 

Off 

Or 

Blinking (not 3 sec) 

First Use  No connected to VxServer 

Successful 
connection 

Wrong PIN/PUK code 

Off 

Blinking(500 ms) 

Blinking (1 sec) 

Blinking (50 ms) 

ГК

 

Атлант

 

Инжиниринг

 – 

официальный

 

представитель

 

в

 

РФ

 

и

 

СНГ

 

+7(495)109-02-08 [email protected] www.bbrc.ru 

Summary of Contents for RMV-514

Page 1: ...elligent Multiport Serial to GPRS Gateway with I O User manual V1 1 GPRS Network Internet Public Fixed IP G P R S VxServer VxComm Driver User s software RMV 514 RS 485 network Flow meter Seismic senso...

Page 2: ...mation furnished by ICP DAS is believed to be accurate and reliable However no responsibility is assumed by ICP DAS for its use or for any infringements of patents or other rights of third parties res...

Page 3: ...Menu 21 4 3 Connecting to the RMV 514 21 4 4 Parameters 22 4 5 Download Upload Parameters 23 4 6 I O Monitor 24 4 7 System 25 4 7 1 Signal Quality 25 4 7 2 Reboot the RMV 514 25 4 7 3 Inputting the PI...

Page 4: ...is broke the GPRS network by something happened It also supports remote I O monitor via virtual COM by Modbus RTU protocol M2M solution will improve the service quality and reduce operating costs Many...

Page 5: ...Internet Public Fixed IP GPRS G P R S G P R S VxServer VxComm Driver PLC Software RMV 514 RS 485 PLC RMV 514 RS 485 PLC RMV 514 RS 485 PLC 1AI 3DO 6DI 1AI 3DO 6DI 1AI 3DO 6DI Remote serial devices mon...

Page 6: ...ports Utility port RS 232 TxD RxD GND use for device configuration and debug COM1 RS 485 D D use for communication with other devices Baud Rate 2400 4800 9600 19200 38400 57600 and 115200 bps Digital...

Page 7: ...Hi Pot Required Supply Voltage 10 VDC 30 VDC Mechanical Casing Plastic Flammability UL 94V 0 materials Dimensions W x L x H 91 mm x 132 mm x 52 mm Installation DIN Rail Environmental Operating Temper...

Page 8: ...DI5 DI COM 07 DI COM DO PWR 08 DO PWR DO 09 DO0 10 DO1 DO GND 11 DO GND N A 12 N A Ain 13 Ain Ain 14 Ain COM Port Power Input Terminal No Pin Assignment Ground for COM 01 GND Utility Port RS 232 02 Rx...

Page 9: ...9 2 3 Dimensions 7 495 109 02 08 sales bbrc ru www bbrc ru...

Page 10: ...10 2 4 DI DO internal Structure and Wire Connection 1 DI Internal Structure 2 DO Internal Structure 7 495 109 02 08 sales bbrc ru www bbrc ru...

Page 11: ...as the following 2 GSM Green The modem LED can indicate the status of GSM module 3 STA Orange The system LED indicated whether the RMV 514 is normal of failed The Power is active The Power is not act...

Page 12: ...tenna B Plug in the normal SIM card Before apply the SIM card confirm it is OK by mobile phone C Pin08 and Pin09 connect to the DC VS and DC GND of the power supply D Follow the section 2 4 to wire th...

Page 13: ...mework 2 0 or above in the PC the section 3 1 can be omitted Microsoft Net Framework Version 2 0 http www microsoft com downloads details aspx FamilyID 0856ea cb 4362 4b0d 8edd aab15c5e04f5 DisplayLan...

Page 14: ...14 1 Press Next to the next step 2 Select the I accept the terms of the License Agreement and Install to the next step 7 495 109 02 08 sales bbrc ru www bbrc ru...

Page 15: ...15 3 The installation process would be going 4 After finishing the installation press Finish to exit the program 7 495 109 02 08 sales bbrc ru www bbrc ru...

Page 16: ...RMV 514 Software RMV 514_Utility_Setup_Vx xx exe The installation figure is as follows 1 Press Next to start the installation procedure 2 Select the installation path The default path is C ICPDAS RMV...

Page 17: ...17 3 Select the Start Menu Folder Press Next to the next step 4 Select additional tasks Press Next to the next step 7 495 109 02 08 sales bbrc ru www bbrc ru...

Page 18: ...18 5 Click Install to start to install the RMV 514 Utility 6 Click Finish to finish installing RMV 514 Utility 7 495 109 02 08 sales bbrc ru www bbrc ru...

Page 19: ...14 Utility The description is as the following 1 Project The parameters of the RMV 514 can be saved as the project file The operation functions include New Open Save Save as and etc 2 Exit Exit the RM...

Page 20: ...Parameter groups There are four parameter groups in the RMV 514 Utility including System and COM Port 3 Parameters Show or set the parameters 4 Description A particular or minute account 5 Status Bar...

Page 21: ...file If the parameters are changed or save the uploading parameters from the RMV 514 you can use this function to save these configurations Save as Saving the file as another name 4 3 Connecting to t...

Page 22: ...ion Protocol RMV 514 support protocol Read only Address The address of the RMV 514 Read only Remote Server The remote VxServer server s IP or domain name Remote Server Port The remote VxServer server...

Page 23: ...data when the length of a data more than fixed length 1 1000 2 Fixed end byte It is as complete a data when receives the fixed end byte Like CR 0x0d 0 255 Com End Param 4 5 Download Upload Parameters...

Page 24: ...AI value It will automation get the IO status per 5 sec Text field A AI DI DO Monitor Online Get I O status succeed Offline Get I O status failed B DI0 DI5 DO0 DO1 Green The voltage logic is high Red...

Page 25: ...ow the GSM signal strength Field Description The strength is divided into 5 sections shown in percentage Operation Read Read the GSM signal strength from the RMV 514 4 7 2 Reboot the RMV 514 Clicking...

Page 26: ...ow would pop up as follows If the number of times for inputting the wrong PIN code is more than the allowed number the PIN code would be ineffective And the PUK code window would pop up 2 Asking for i...

Page 27: ...5 Inquiring System status Press System System status in tool menu and the window would show the RMV 514 working status Field instruction Connect Status Connected Get RMV 514 status is succeed Disconne...

Page 28: ...28 4 7 6 Inquiring Firmware Version Press System Firmware Version in tool menu and the window would show the versions of the RMV 514 Utility and firmware 7 495 109 02 08 sales bbrc ru www bbrc ru...

Page 29: ...y Download Microsoft Net Framework Version 2 0 http www microsoft com downloads details aspx FamilyID 0856eacb 4362 4b0 d 8edd aab15c5e04f5 DisplayLang en Download VxServer software http m2m icpdas co...

Page 30: ...0 5 2 Setting the VxServer and VxComm Driver 1 Verify that the device has been connected up 2 Execute VxComm Utility then click Search Servers RMV 514 RMV 514 7 495 109 02 08 sales bbrc ru www bbrc ru...

Page 31: ...31 3 Select your device then click Add Server s 4 IP Range check Maps virtual COM ports to Port I O on servers RMV 514 RMV 514 7 495 109 02 08 sales bbrc ru www bbrc ru...

Page 32: ...Options please follow the below parameter settings Parameters Fixed value Keep Alive Time 1 Connection Broken 3 Connect Timeout 1 Command Port 10000 Virtual I O Port 9999 7 495 109 02 08 sales bbrc r...

Page 33: ...nfigure the system parameter via RMV 514 utility it can also get the I O status and control the DO I O control methods please refer the chapter 6 II Port 1 The Port 1 mapping to the COM1 of RMV 514 Po...

Page 34: ...ding the Port I O of VxComm Utility to select the com port of RMV 514 Utility then click RMV 514 Utility Connect 9 The remaining steps please refer to Chapter 4 RMV 514 7 495 109 02 08 sales bbrc ru w...

Page 35: ...uest 00 Net ID 1 Byte 01 Function code 1 Byte 02 03 Starting address 2 Byte 04 05 DO count 2 Byte Response 00 Net ID 1 Byte 01 Function code 1 Byte 02 Byte count of response B DO count 7 8 1 Byte 03 B...

Page 36: ...5 00 1 Byte Response 00 Net ID 1 Byte 01 Function code 1 Byte 02 03 Starting address 2 Byte 04 FF High 00 Low 1 Byte 05 00 1 Byte 5 Set multi Digital Output Function code 15 Request 00 Net ID 1 Byte 0...

Page 37: ...00 Read DI0 R 00001 0x01 Read DI1 R 00002 0x02 Read DI2 R 00003 0x03 Read DI3 R 00004 0x04 Read DI4 R 00005 0x05 Read DI5 R 3 AI status Function Code 4 Address Data Address Description Attribute 30027...

Reviews: