ICP DAS, MDC-211-ZT user manual , v1.0 Page 32
Copyright © 2018 by ICP DAS. All rights are reserved.
4.
Parameter Descriptions
This chapter introduces a variety of setting parameters and examples for the users to follow
and set up the modules.
4.1.
Communication Interface Parameter Descriptions
4.1.1.
ZigBee Communication Interface
Parameter descriptions
Table 4.1 shows the descriptions for the ZigBee parameters, setting range and notes.
Table 4.1 ZigBee related parameter descriptions
Item
Description
Note
Pan ID
ZigBee
Network ID
Setting range: 0x0000 ~ 0x3FFF
Must set the same Pan ID in the same domain network
Node ID
ZigBee
Node ID
Coordinator/Host: Fixed to 0x0000
Router/Slave: setting range within 0x0001 ~ 0xFFF7
No duplicate node number under the same domain
network
RF Channel
Radio Frequency
Channel Code
Setting range: 0 ~ F (2405~2480 MHz)
Must set to the same if in the same domain network
RF Power
Transmit Power
Code
Signal strength from small to large: 0~F. Factory default: 8
(Compatible with the CE/FCC specification limitation)
This parameter is only for testing purposes. If the users
change it that is a personal behavior, the ICP DAS cannot
guarantee that the user-changed parameter is still
compatible with the CE/FCC specification limitation, and
ICP DAS assumes no legal liability for any damage
resulting from the change of the parameter.
Encryption
(AES 128)
Communication
Encryption
Enable or disable
Must set to the same if in the same domain network