iNS-308 User Manual
Copyright
©
2022 ICP DAS CO., Ltd. All Rights Reserved.
- 44 -
7.3 Modbus Register Table
0xxxx: DO address (Base 0)
Address
CH
Description
Range
Access Type
00000~00007 8 PoE Enable
0=OFF, 1=ON
R/W
00032
1
PoE CDPL enable
Auto Class Define Power Limit
0=Disable
1=Enable
R/W
00040
1 Ethernet Jumbo Frame
0=Disable
1=Enable
R/W
00041
1 Ethernet Loop Detect
0=Disable
1=Enable
R/W
00042
1 Ethernet Broadcast storm filter
0=Disable
1=Enable
R/W
3xxxx: AI address (Base 0)
Address
CH
Description
Range
Access Type
30000~30007 8 PoE Port Current (mA)
2-Byte, DEC(mA)
R
30032~30040 8 PoE Port watt (mW)
2-Byte, DEC(mW)
R
30096~30103 8 PoE Port TEMP (
°
C)
2-Byte, DEC(
°
C)
R
30129~30137 8 PoE Port PD Device Class
Detect PD Class 0~4
5 is unknow
R
30160
1 PoE Port Volt
2-Byte, DEC(V)
R
30192~30200 8 Ethernet Link status
1 =>100M Full
2 =>100M Half
3 =>10M Full
4 =>10M Half
5 =>unlink
R
30256
1 Module Name
2-Byte, Hex 0x0308
R
30257
1 FW version
2-Byte, Hex
R
30258
1 HW version
2-Byte, Hex
R