I-7540D CAN-Ethernet Gateway User’s Manual (Version 1.8, March/2021)
75
4.12
99$P0105BBDSP
Description:
Change the RS-232 configuration of the I-7540D into EEPROM
Syntax: 99$P0105BBDSP
99$P0105
Command character
BB
RS-232 Baud rate
D
Data bit
0 = 7 bits data formation
1 = 8 bits data formation
S
Stop bit
0 = 1 stop bit
1 = 2 stop bits
P
Parity bits
0 = None
1 = Even
2 = Odd
RS-232 Baud rate list
Response:
Valid Command: OK
Invalid command: ERROR
BB
Description
00
110 bps baud rate of RS-232
01
150 bps baud rate of RS-232
02
300 bps baud rate of RS-232
03
600 bps baud rate of RS-232
04
1200 bps baud rate of RS-232
05
2400 bps baud rate of RS-232
06
4800 bps baud rate of RS-232
07
9600 bps baud rate of RS-232
08
19200 bps baud rate of RS-232
09
38400 bps baud rate of RS-232
0A
57600 bps baud rate of RS-232
0B
115200 bps baud rate of RS-232