I-7540D CAN-Ethernet Gateway User’s Manual (Version 1.8, March/2021)
61
4.3
eIIIIIIIILDD…<CR>
Description:
Send or receive an extended CAN data frame.
Syntax: eIIIIIIIILDD…<CR>
e
Stands for the extended (2.0B) data frame.
IIIIIIII
29 bits Identifier (00000000~1FFFFFFF)
L
Data length (0~8)
DD…
Input data frame value according to the data length
(00~FF)
Response:
Valid command: No response
Invalid command: ?<Error Code><CR>
Note:
It is necessary to enable the “Error Response” function in the I-7540D
Utility, in order to receive Syntax and/or communication error information
at the host PC.
Example:
Command (
ASCII
): e123456783112233<CR>
Command (
HEX
): 65 31 32 33 34 35 36 37 38 33 31 31 32 32 33 33 13
Send a CAN message with an extended data frame.
ID
=0x12345678,
DLC
=5,
data1
=0x11,
data2
=0x22,
data3
=0x33.
Note:
This command can only be accepted by 7540D’s port
10003