3.3.6. CAN Splitting Rule Configuration
This field is used to configure splitting rules of the device. Splitting rule is used to
split one CAN FD frame to multiple CAN frames (Max. 8). It is useful for user to split
datas in one CAN FD frame to multiple CAN frames. Each device maximum supports 32
splitting rules.
The splitting rule field is similar to merging rule field. After setting the rules on “Splitting
Rule Configuration” frame, rules will be displayed on the frame list. The smaller the “No”
number, the higher the process priority level. User can press the “Add” button to add a
new rule or press the “Modify” button to modify the selected rule.