background image

 

 

GRP-2841M-5GE User Manual 

Version 1.1.0 

Page

24 

 

Copyright ©  2022 ICP DAS Co., Ltd. All Rights Reserved    E-mail: [email protected] 

5.2.3  Storage Information 

The 

“Storage Information” page provides information about "Micro SD Card". 

 

 Micro SD card 

 Size:           Total  storage size 

 used:           Used size 

 Available:   Free space in the storage 

 Path:           The mount point in   the file system. 

 

 

5.3 

Network 

5.3.1  Ethernet 

The 

“Ethernet” page provides basic settings for Ethernet0 (LAN1) and Ethernet1 (LAN2) 

 

(1) IP Address:    Ethernet IP. 

(2) Mask:             Ethernet mask. 

(3) Gateway:       Gateway IP. 

 

 

Summary of Contents for GRP-2841M-5GE

Page 1: ...User Manual Version 1 1 0 Aug 2022 GRP 2841M 5GE 5G Edge Computing Controller...

Page 2: ...tor 9 3 3 Serial Port Gateway Application 10 3 4 Node RED Application 10 4 Hardware 11 4 1 Appearances 11 4 2 Dimension 12 4 3 LED Indicators 13 4 4 Rotary Switch 13 4 5 Mounting the Expansion Compone...

Page 3: ...store Factory 36 5 4 7 Time 36 5 5 VxServer 37 5 5 1 VxServer 37 5 6 RTU Client 39 5 6 1 RTU Client 39 5 6 2 FTP Test 43 5 6 3 Email Test 43 5 6 4 Modbus Test 44 6 Example 46 6 1 5G Router Application...

Page 4: ...GRP 2841M 5GE User Manual Version 1 1 0 Page 4 Copyright 2022 ICP DAS Co Ltd All Rights Reserved E mail service icpdas com...

Page 5: ...P DAS reserves the right to change this manual at any time without notice The information furnished by ICP DAS is believed to be accurate and reliable However no responsibility is assumed by ICP DAS f...

Page 6: ...5G communication module providing Ethernet and Wi Fi option data transmission It also has built in GPS GNSS functionality and can also be used as a GPS tracking system for vehicle management or marine...

Page 7: ...es 64 bit Hardware Serial Number Yes for software copy protection LED Indicators 6 LEDs PWR NET RUN L1 L2 L3 Rotary Switch 1 x 10 Position 0 9 3G System Frequency Band WCDMA B1 B2 B3 B4 B5 B6 B8 B19 4...

Page 8: ...nt Data Transmission Rate 802 11b 1 2 5 5 11 Mbps 802 11g a 6 9 12 18 24 36 48 54 Mbps 802 11n MCS0 to MCS7 Frequency Range 2412 MHz 2484 MHz 4 9 GHz 5 975 GHz Transmit Power 2 4 GHz 18 dBm 5 GHz 13 5...

Page 9: ...GRP 2841M 5GE User Manual Version 1 1 0 Page 9 Copyright 2022 ICP DAS Co Ltd All Rights Reserved E mail service icpdas com 3 Application Architecture 3 1 5G Wireless Router 3 2 Remote Video Monitor...

Page 10: ...hts Reserved E mail service icpdas com 3 3 Serial Port Gateway Application 3 4 Node RED Application About Node RED please download Node RED package from https www icpdas com en download index php mode...

Page 11: ...GRP 2841M 5GE User Manual Version 1 1 0 Page 11 Copyright 2022 ICP DAS Co Ltd All Rights Reserved E mail service icpdas com 4 Hardware 4 1 Appearances...

Page 12: ...GRP 2841M 5GE User Manual Version 1 1 0 Page 12 Copyright 2022 ICP DAS Co Ltd All Rights Reserved E mail service icpdas com 4 2 Dimension Units mm...

Page 13: ...witch The description is as follows 1 0 Normal mode default position 2 9 If the user sets the rotary switch to 9 and then restarts the device the Ethernet IP will be set to 192 168 255 1 It is useful...

Page 14: ...he Expansion Components GRP 2841M 5GE has two mini pcie sockets and one M 2 socket to expand the wireless communication function If you want to install the Wi Fi module please refer to the following i...

Page 15: ...e icpdas com 2 Hold the communication module and then carefully insert it into the socket If the communication module is RYWDB00 Wi Fi module please plug it into the mini pcie socket_2 3 Fasten the co...

Page 16: ...ge 16 Copyright 2022 ICP DAS Co Ltd All Rights Reserved E mail service icpdas com 5 Close the cover and then fasten the screws 4 6 Install the SIM card Before using mobile communication users need to...

Page 17: ...nual Version 1 1 0 Page 17 Copyright 2022 ICP DAS Co Ltd All Rights Reserved E mail service icpdas com 6 Remove stripped screws and then remove the cover 7 Insert the SIM card 8 Close the cover and th...

Page 18: ...tenna GRP 2841M 5GE has four antenna ports which can be used to connect 5G and GPS antennas To install the antenna simply screw the antenna into the connector and place the antenna in the designated p...

Page 19: ...1610MHz 1710 2200MHz 2300 2690MHz 3300 3800MHz 4200 5000MHz 5150 5925MHz Regarding GPS GNSS antennas there are the following options Model Ant Type Employment Band ANT 115 P1 Passive Antenna GPS 5G Mo...

Page 20: ...d All Rights Reserved E mail service icpdas com 5 Web Utility 5 1 Login the Utility Please login before using the web utility Default IP is 192 168 255 1 Default Mask is 255 255 0 0 Default username i...

Page 21: ...Co Ltd All Rights Reserved E mail service icpdas com 5 2 Information 5 2 1 Device Information The Device Information page provides basic device information Serial Number Serial number of ICPDAS produc...

Page 22: ...2 Network Information The Network Information page provides basic network information Ethernet0 Ethernet1 Ethernet information Mode Only support static IP MAC Address Unique identifier assigned to th...

Page 23: ...tion 2 IMEI IMEI number of communication module PIN Code The status of the PIN code READY PIN code is ready SIM PIN Need PIN code SIM PUK Need PUK code SIM failure Access to SIM card failure Register...

Page 24: ...Information page provides information about Micro SD Card Micro SD card Size Total storage size used Used size Available Free space in the storage Path The mount point in the file system 5 3 Network...

Page 25: ...work PIN Code The PIN code is a 4 character number provided by the SIM card provider Phone Number It is generally filled in as 99 1 or 99 depending on the SIM card provider APN Access point name Pleas...

Page 26: ...ime System retry interval Enable Function Whether to enable this function This setting will run immediately 5 3 5 DNS The DNS page provides the settings of the DNS server IP Primary DNS Server The dev...

Page 27: ...name of the DDNS service provider Domain Name The domain name registered by the user Username The username of DDNS service Password The password of DDNS service Period The time period in seconds to up...

Page 28: ...erver The IP of the VPN service provider VPN Username The username of the VPN service VPN Password The username of the VPN service DDNS DDNS Server The IP of the DDNS service provider DDNS Domain Name...

Page 29: ...ddress on the server FTP Period The time period in seconds to update the address FTP Passive Mode Whether to enable passive mode VPN Enable Whether to Enable this function This setting will run after...

Page 30: ...able DHCP Server function 5 3 9 Routing Port Mapping White list The Routing Rule page provides setting of routing rules Routing Rule IP IP address Mask The mask will affect the number of IPs managed b...

Page 31: ...N1 The Routing Mapping Rule page provides setting of port forwarding Port Mapping Rule Type Protocol type supports TCP and UDP From The interface from which the socket comes Port The port from which t...

Page 32: ...com Whitelist Rule From Connection interface IP IP addresses allowed to connect For Example Only device at 192 168 255 100 of eth0 are allowed to connect Warning Please set it carefully devices not i...

Page 33: ...ll ping the Target IP and display the result below Traceroute This tool will trace the routing path to the Target IP and display the results below Route Information This tool will show route settings...

Page 34: ...5 4 System 5 4 1 Password The Change Password page provides password settings Password Enter the new password Confirm Confirm the new password 5 4 2 Reboot The Reboot page provides the function of re...

Page 35: ...d Restore page provides backup and restore of settings Backup Press the Backup button to back up the settings to the user s PC Restore Press the Browse button to select the file and then press the Res...

Page 36: ...vides the function to restore the settings to the factory settings 5 4 7 Time The Time page provides the time information of the device Set Time Set the device s time to be the same as your computer N...

Page 37: ...P Function If this function is enabled the device will automatically update the time 5 5 VxServer Through VxServer and VxComm Utility users can create a virtual COM port on a remote PC to communicate...

Page 38: ...Baudrate This value depends on your serial device 115200 means baud rate is 115200 bps 57600 means baud rate is 57600 bps 38400 means baud rate is 38400 bps 19200 means baud rate is 19200 bps 9600 mea...

Page 39: ...to 1000 bytes default This value is restricted by the network protocol 5 6 RTU Client The RTU device uploads its I O information Modbus RTU TCP device I O information and GPS information to the RTU C...

Page 40: ...f UART COM1 3 Data bit The data bit of UART COM1 3 Parity The parity bit of UART COM1 3 Stop bit The stop bit of UART COM1 3 Modbus Timeout ms Modbus communication timeout value Enable Firmware Enable...

Page 41: ...ce 1 Port The Port of Modbus TCP device DI Number The number of DI channel DO Number The number of DO channel AI Number The number of AI channel AO Number The number of AO channel DI Address The start...

Page 42: ...name FTP Port FTP server port number FTP Username The username of FTP account FTP password The password of FTP account Enable FTP Function Enable FTP report function Email From The email will be sent...

Page 43: ...e and moved to the LOGFILE folder If users enable the Enable FTP Function Enable Email Function these old log files will be copied to FTP_UPLOAD MAIL_UPLOAD and sent 3 Use to separate each email addre...

Page 44: ...ess 1 Email Server The email server IP Email Server Port The email server port number 2 Email Username The username of email account Email Password The password of email account Test button Press this...

Page 45: ...GRP 2841M 5GE User Manual Version 1 1 0 Page 45 Copyright 2022 ICP DAS Co Ltd All Rights Reserved E mail service icpdas com...

Page 46: ...hows the steps to share 5G network to 3 XPAC8000 1 The Ethernet configuration of XPAC8000 is as follows IP is from 192 168 0 10 to 192 168 0 12 Mask is 255 255 0 0 Gateway is 192 168 27 31 2 Fill in t...

Page 47: ...work Reconnect function to ensure that the mobile network is always online usually the ISP will disconnect once every 1 to 3 days Server IP can fill in user server IP or Google DNS server IP 8 8 8 8 I...

Page 48: ...l Rights Reserved E mail service icpdas com 5 Fill in the routing rules to share the 4G 5G network Rule 0 will share the 4G 5G network to IP addresses from 192 168 0 1 to 192 168 0 255 After finishing...

Page 49: ...Server and IP Camera Application This example shows the steps to share 3G 4G network to ET 7044 and IP camera 1 The Ethernet configuration of ET 7044 is as follows IP is from 192 168 0 20 to 192 168...

Page 50: ...ishing all the settings click Modify 4 Enable the Network Reconnect function to ensure that the mobile network is always online usually the ISP will disconnect once every 1 to 3 days Server IP can fil...

Page 51: ...P device through the Internet Rules 0 to 2 bind the ports of the 4G 5G network interface to the Target IP and Target port After finishing all the settings click Modify Bind port 12080 of 4G 5G network...

Page 52: ...ersion 1 1 0 Page 52 Copyright 2022 ICP DAS Co Ltd All Rights Reserved E mail service icpdas com 7 To view the IP camera image from a web browser please enter the IP address or domain name of the GRP...

Page 53: ...ontrol Temperature Monitor This example shows the remote control application through Serial port to 5G gateway function 1 Connect the device DL 100 or PLC to the serial port of the GRP device 2 Open V...

Page 54: ...Reconnect function to ensure that the mobile network is always online usually the ISP will disconnect once every 1 to 3 days Server IP can fill in user server IP or Google DNS server IP 8 8 8 8 If the...

Page 55: ...1 1 0 Page 55 Copyright 2022 ICP DAS Co Ltd All Rights Reserved E mail service icpdas com 5 Fill in the Server IP and Server Port default 11000 After finishing all the settings check the Enable field...

Page 56: ...ase refer to http www icpdas com en product guide Software Applications VxServer 8 After the GRP device is connected to VxServer follow the steps below A Open VxComm Utility Note 1 VxComm Utility vers...

Page 57: ...ion 1 1 0 Page 57 Copyright 2022 ICP DAS Co Ltd All Rights Reserved E mail service icpdas com E Select the starting number of the virtual serial port F Change the settings tab to Server Options and se...

Page 58: ...Reserved E mail service icpdas com 9 The user will see the virtual COM ports COM5 and COM7 in this example If the user cannot open them please follow the below steps to open the virtual COM port A Cli...

Page 59: ...ort 10001 is RS 232 port 10002 is RS 485 1 Please connect your device M 7017 or PLC to RS 485 of GRP device The baudrate of Modbus device is 9600 bps and the data format is 8N1 The baudrate of Card Re...

Page 60: ...to 3 days Server IP can fill in user server IP or Google DNS server IP 8 8 8 8 If the user uses MDVPN please make sure that the server IP does not deny the ICMP service Ping After finishing all the se...

Page 61: ...GRP 2841M 5GE User Manual Version 1 1 0 Page 61 Copyright 2022 ICP DAS Co Ltd All Rights Reserved E mail service icpdas com...

Page 62: ...lease reboot the device to enable the setting 7 After rebooting the GRP device will automatically connect to VxServer 8 After the GRP device is connected to VxServer user can connect to 127 53 0 1 100...

Page 63: ...RTU API to collect and control remote Modbus RTU and Modbus TCP I O with RTU client server This system has ET 7050 M 7022 and PLC 1 Please connect the RS 485 or Ethernet of the device ET 7k or M 7k m...

Page 64: ...E mail service icpdas com online usually the ISP will disconnect once every 1 to 3 days Server IP can fill in user server IP or Google DNS server IP 8 8 8 8 If the user uses MDVPN please make sure tha...

Page 65: ...t 2022 ICP DAS Co Ltd All Rights Reserved E mail service icpdas com 3 Select ET 7050 in the list and then click Add the web will display all I O number information as shown below Modify the Device Nam...

Page 66: ...d All Rights Reserved E mail service icpdas com 4 Select M 7022 in the list and then press the Add button the web will display all I O number information as shown below Modify the Device Name and Devi...

Page 67: ...ICP DAS Co Ltd All Rights Reserved E mail service icpdas com 5 Select Custom in the list and then press the Add button the web will display all I O number information as shown below Modify the Device...

Page 68: ...2022 ICP DAS Co Ltd All Rights Reserved E mail service icpdas com 6 Select the Modbus Test function and then press the Test button to test the settings If the result is successful follow the next step...

Page 69: ...erved E mail service icpdas com 7 Configure Main Info Tab Fill in the Server Address and Server Port of RTU Center Fill in the Station ID different from other RTU equipment Fill in the Data Update Per...

Page 70: ...r and then follow the steps below to add RTU devices A Click the New Device icon B Enter the alias of the GRP device C Fill in the Station ID as the Station ID of GRP device 9 After reboot the GRP dev...

Page 71: ...TU API from the RTU center webpage and unzip it There are RTU API library and some C VB Net VC6 demos as shown below 12 Copy the pre built demo to the folder in the RTU Center The demo must be in the...

Page 72: ...n to get all station information B Fill in the Station ID as the Station ID of GRP device C Press the Read Data button to read the local IO data Because the GRP device has no local IO we get the error...

Page 73: ...GRP 2841M 5GE User Manual Version 1 1 0 Page 73 Copyright 2022 ICP DAS Co Ltd All Rights Reserved E mail service icpdas com...

Page 74: ...All Rights Reserved E mail service icpdas com 6 6 RTU Client for Remote Control Application with OPC DA Server 1 For RTU Client and RTU Center please refer to the previous section 2 Open NAPOPC M2M DA...

Page 75: ...right 2022 ICP DAS Co Ltd All Rights Reserved E mail service icpdas com 3 Double click the device node to modify the device name 4 Now users can use OPC Client to read I O data from NAPOPC M2M DA Serv...

Page 76: ...rol Application with InduSoft This example shows how to use SCADA InduSoft to control monitor the remote I O 1 For RTU Client RTU Center and OPC Server please refer to the previous section 2 Right cli...

Page 77: ...0 Page 77 Copyright 2022 ICP DAS Co Ltd All Rights Reserved E mail service icpdas com 4 Configure label names and item columns A Fill in the Tag Name B Double click the Item column and select the poi...

Page 78: ...yright 2022 ICP DAS Co Ltd All Rights Reserved E mail service icpdas com 6 8 Email or FTP report I O logger file This example shows how to use GRP devices to periodically report I O recorder files 1 F...

Page 79: ...2 Configure Email FTP function in Email FTP tab A Fill in Data Log Interval to record I O data to the log file B Fill in Max Time per log file to report log files C To use FTP function fill in all se...

Page 80: ...n 1 1 0 Page 80 Copyright 2022 ICP DAS Co Ltd All Rights Reserved E mail service icpdas com 3 Finally enable this function in the Main Info tab If the user does not need to send data to the RTU Center...

Page 81: ...Appendix A Revision History This chapter provides revision history information to this document The table below shows the revision history Version Date Description of changes 1 0 0 2022 05 13 The Firs...

Reviews: