9
8. Display
No.
Name
Function
ON/OFF
Short button press of ON/OFF turns the pump controller on
Press and HOLD ON/OFF button for
3 seconds t
o turn the controller off
.
Press and Hold
ON/OFF for 3 seconds to
reset any error messages
DIGITAL DISPLAY
(RUNNING)
PX.X =
Real time pressure in Bar
CX.X
= Real time current in amps
Symbol moving clockwise = Flow
(quick press of RESET button 9 to change modes)
- - -
symbol stationary = No Flow
-P-
displayed = Over pressure protection activated
-A-
displayed = Frequent start protection active
OL
flashing = Overload protection setting
UL
flashing = Underload protection setting
PF
= Low Flow protection setting
Pr
= Max run time protection setting
DIGITAL DISPLAY
(PROGRAMMING)
PX.X =
Start and Stop Pressure
CX.X
= Current
F1
= Mode 1 (pressure controller)
Default cut in 2.2 bar
F2
= Mode 2 (pressure switch)
Default cut in 2.2 bar, Default cut out 9 bar
OL
= Overload protection setting
Default setting C0.0
UL
= Underload protection setting
Default setting C0.0
PF
= Low Flow protection setting
Default setting 1 (Enabled)
Pr
= Maximum run time setting
Default setting 000 (Inactive)
POWER
GREEN LED POWER constant
– Power connected
MODE 1
Orange LED MODE 1 constant
– pump is in precise control mode
MODE 2
Orange LED MODE 2 constant
– pump is in precise control mode
LACK OF WATER
RED LED flashing
- pump short of water
RED LED constant
- pump awaiting 24 hour restart
PLUS
To increase value of parameter ( Located bottom left, )
MINUS
To decrease value of parameter ( Located bottom centre, marked -)
RESET
To set and save a parameter ( Located bottom right, marked RESET)