4 CABLING
CAUTION : positive security/fail safe relays - contacts given for powered radar.
12-60 VDC – 10-30 VAC
PIN nr
Color
Power + 2
relays* (NO/NC)
Power + 1 relay
(NO/NC) + RS232*
Power + 2 relays (NO)
+ RS232*
1
RED
Power ~ (AC), + (DC)
2
BLUE
N/A
N/A
COM relay 2*
3
BLACK
Power ~(AC), - (DC GND)
4
BROWN
NC relay 2*
GND RS232*
GND RS232*
5
WHITE
COM relay 1
COM relay
COM relay 1
6
GREY
NO relay 1
NO relay
NO relay 1
7
YELLOW
NC relay 1
NC relay
NO relay 2*
8
GREEN
COM relay 2*
RX radar (RS232)*
RX radar (RS232)*
9
PINK
NO relay 2*
TX radar (RS232)*
TX radar (RS232)*
* : RS-232 and relay 2 are optional features on specific TMA- configurations.
USER’S OUTPUTS
Resistive load : 30 VAC 0.3A - 30 VDC 0.3A
Inductive load : 30 VAC 0.2A - 30 VDC 0.3A
REMARKS
•
Make sure the plug is fully inserted in the socket and the cap is firmly tightened on the socket.
•
Please disconnect the radar from power before maintenance intervention.
5 TECHNICAL FEATURES
TMA
Protection level
IP 65
Power supply
12 – 60 VDC - 10 – 30 VAC
Power consumption
See tune up procedure
User output
Inverted relay contact(s) :
Resistive load: 30 VAC 0.3 A – 30 VDC 0.3 A
Inductive load: 30 VAC 0.2 A – 30 VDC 0.3 A
LED on front face
Optional RS-232
Temperature range
-20° C to +60° C
Dimensions
L68 x H199 x D119 mm
Weight
350 gr
Wiring & connectors
Weipu connector
Figure 5 : connector Weipu SP1712/P9