background image

 

 

Figure 2: TMA-011 LV and 
MV radar connector - Weipu 
SP1712/P9

 

Figure 3: TMA-011 HV 
radar connector - Weipu 
SP2112/P7 

CABLING 

 CAUTION: positive security/fail safe relays - contacts given for powered radar. 

 

 

 

HV 

(100-240 VAC)

 

PIN nr 

Color 

Function 

BLUE

 

~ Power Supply 

 

BROWN

 

~ Power Supply

 

YELLOW

/GREEN

 

EARTH 

WHITE 

Relay - COM

 

GREY

 

Relay - NO

 

YELLOW

 

Relay - NC

 

PURPLE

 

Do not connect

 

 
USER’S OUTPUTS  
Resistive load: 30 V AC 0.3 A - 60 V DC 0.3 A 
Option 250 V relay: 250 V AC - 30 V DC – 0.3 A 
 
REMARKS 

 

Make sure the plug is fully inserted in the socket and the cap is firmly tightened on the socket. 

 

Please disconnect the radar from power before maintenance intervention. 

 

 

LV 

(12-60 VDC – 10-30 VAC) 

& MV 

(21-75 VDC – 15-54 VAC)

 

PIN nr 

Color 

Function 

RED

 

Power ~ (AC), + (DC)

 

BLUE

 

Do not connect

 

BLACK  

Power ~(AC), - (DC GND) 

BROWN

 

Do not connect 

WHITE or 

PURPLE

  Relay - COM

 

GREY

 

Relay - NO

 

YELLOW 

Relay - NC

 

GREEN

 

Do not connect

 t 

PINK 

or

 

ORANGE

  Do not connect

 

Summary of Contents for TMA-011

Page 1: ...TION 4 2 1 IDENTIFICATION LABEL 4 2 2 SERIAL NUMBER 4 3 SETTINGS 4 SAFETY PRECAUTIONS 5 CABLING 6 DESCRIPTION OF PARAMETERS 7 1 SELF MONITORING 7 2 RF CHANNEL 7 3 DETECTION DISTANCE 7 4 DETECTION DIRE...

Page 2: ...CONNECTOR WEIPU SP1712 P9 6 FIGURE 6 TMA 011 HV RADAR CONNECTOR WEIPU SP2112 P7 6 FIGURE 5 TMA 011 LV AND MV RADAR CONNECTOR WEIPU SP1712 P9 8 FIGURE 6 TMA 011 HV RADAR CONNECTOR WEIPU SP2112 P7 8 FIG...

Page 3: ...nd check the following items are in the box A Radar with rear side socket B Sticker for front face C Cable with connector D Mounting bracket E User s guide and tune up procedure 2 Set the encoders acc...

Page 4: ...ket See tune up procedure for more details Figure 1 delivery 2 LABELS LOCATION 2 1 IDENTIFICATIONLABEL 2 2 SERIALNUMBER 3 SETTINGS You can set different parameters through 2 encoders allowing 16 posit...

Page 5: ...ust be made whilst the power supply is switched off Ensure the wiring is correct as shown in the manual before switching on the power supply Never use a damaged radar or cable Opening the outer casing...

Page 6: ...ot connect USER S OUTPUTS Resistive load 30 V AC 0 3 A 60 V DC 0 3 A Option 250 V relay 250 V AC 30 V DC 0 3 A REMARKS Make sure the plug is fully inserted in the socket and the cap is firmly tightene...

Page 7: ...rocedure for further information 2 RF CHANNEL This parameter allows to shift the radar s frequency If two units face each other they must be put on different channels as to not interfere with each oth...

Page 8: ...3 4 5 6 7 8 9 A B C D E F Detection distance 8 12 16 30 m Factory setting 0 2 ENCODER 2 Besides green LED at the right facing the housing Encoder position 0 1 2 3 4 5 6 7 8 9 A B C D E F Uni bi direct...

Page 9: ...nimum of 750 milliseconds 2 WHEN THE SELF MONITORING DETECTS AN ERROR The two LEDs blink quickly 2 or 4 quick flashes followed by a 1 sec break depending on the detected error INSTALLATION GUIDE 1 GEN...

Page 10: ...4V AC 50 60 Hz 21 75V DC 100V 240V AC 50 60 Hz Power consumption 12V DC 1 2 W 220V AC 2 W User output Inverted relay contact Resistive load 30V AC 0 3 A 60V DC 0 3 A Option 250 V relay 250 V AC 30 V D...