8
COMMUNICATION MODULE INSTALLATION
INSTALLATION
1 Using the CM’s (communication module) mounting tabs as a template align the CM on
the wall where it is to be mounted. Mark the wall with a pencil or awl through the holes in
the mounting tabs while holding the CM level. See Figure 3 and the Location
Requirements on page 7.
2 Drill two holes in the wall where the marks were made in the Step 1 using a portable drill
and the appropriate type (standard or masonry) of 3/8” drill bit. See Tool Requirements
on page 4.
3 Insert one Nylon Toggle Anchor (Table 1 on page 7) in each hole drilled in Step 2. Gently
tap the anchors into the holes using a hammer until they are flush with the wall.
4 Align the CM with the anchors in the wall and install the two mounting screws (Table 1 on
page 7) to secure the CM to the wall.
Wall mount tabs
Figure 3
Wire Tie
CM (communication module)
Wrap & Mount
Ensure the CM is level
Leave some excess cable by CM when routing network cables to provide proper
strain relief. Use the included wire tie wraps and 3/4” square adhesive wire tie
mounts to secure excess cables and wiring to the wall by the CM.
Drill 3/8” diameter hole and
fold the nylon toggle anchor
in the middle.
Insert anchor into hole and
Align mounting tabs of CM over
tap flush with a hammer.
anchors. Insert screw and
tighten until flush with mounting
tabs. Do not overtighten.
Installing Nylon Toggle Anchors