15
MANAGEMENT
15-5
Management Tools screen
Management > Management Tools
■
HTTP/HTTPS
HTTP and HTTPS are the protocols to access from a web browser.
L
When you set HTTP settings and HTTPS settings to “Enable,” you can not access the setting screen using a browser.
1
HTTP ����������
Select whether to allow access using the HTTP protocol.
(Default: Enable)
2
HTTP Port��������
Enter the HTTP Port number
(Default: 80)
• Range: 80, or 1024 ~ 65535.
• Some of the RoIP Gateway’s ports cannot access HTTP.
L
Enter a different port number from HTTPS, Telnet or SSH.
3
HTTPS ���������
Select whether to allow access using the HTTP protocol.
(Default: Disable)
L
HTTPS access is more secure than Telnet or HTTP access because the
passwords and data are encrypted.
4
HTTPS Port �������
Enter the HTTPS Port number.
(Default: 443)
• Range: 443, or 1024 ~ 65535.
• Some the RoIP Gateway’s ports cannot access HTTPS.
L
Enter a port number different from HTTP, Telnet or SSH.
1
2
3
4