2
SETTING UP THE TRANSCEIVERS
2-12
NXDN Conventional mode operation
Connection Port Settings > Digital Transceiver (D-TRX)
1
Open the Digital Transceiver (D-TRX) screen.
(Connection Port Settings > Digital Transceiver (D-TRX))
2
In [Digital Transceiver], select a port (example: D-TRX1), in [Digital Transceiver System], select a system
(example: NXDN Conventional), and then click <Apply>.
q
Select
w
Select
e
Click
3
Enter the settings for the Repeater B (example: IC-FR5000), such as the IP address, Port Number, and
Connection Key Code.
Enter
4
Click <Apply>.
5
In Digital Transceiver Connection, click <Connect> to connect to the Repeater B.
•
“Connecting” is displayed when the RoIP Gateway is successfully connected.
6
Set up the Repeater C as the same way.
[D-TRX1]
[D-TRX2]
[EXT1]
SWITCH
Repeater B
IC-FR5000
(192.168.0.3)
Repeater C
IC-FR5000
(192.168.0.4)
Icom trasnsceiver
IC-F5060
CH5
CH25
[LAN]
VE-PG4
(192.168.0.1)
B
C
A
IP Network
P
0
P
1
P
2
P
3
P
4
P
0
P
1
P
2
P
3
P
4
■
Connecting to a digital radio through the network
Connect a digital radio to the VE-PG4 through the network, and set in [Digital Transceiver Connection].
(
☞
Continued on the next page)