16
MENU SCREEN
16-64
■
DV Set items (Continued)
RX Record (RPT)
(Default: ALL)
DV Set > RX Record (RPT)
The transceiver can record the data of up to 50 individual calls.
When the received signal includes a status message (“UR?” or “RPT?”) that
is sent back from the access repeater, you can record up to 50 messages or
only the latest one, in the Received Call Record.
• ALL:
Records up to 50 calls.
• Latest Only: Records only the latest call.
[RX>CS] Key
(Default: Call Sign Capture)
DV Set > [RX>CS] Key
Select the Call Sign Capture key (
) operation when it is held down.
• Call Sign Capture: While holding down
, the RX history is displayed.
After releasing, the last received call station’s call sign
is set to “TO” (destination).
• RX>CS List:
When you hold down
for 1 second, the RX history
is displayed. Push D-pad(
) to select a call sign to set
to “TO” (destination), and then push D-pad(Ent).
BK
(Default: OFF)
DV Set > BK
The BK (Break-in) function allows you to break into a conversation, where
the two other stations are communicating with call sign squelch enabled.
• OFF: Turns the function OFF.
• ON: Turns the function ON.
“BK” appears on the display.
NOTE:
The BK function is automatically turned OFF when transceiver is
turned OFF.
EMR
(Default: OFF)
DV Set > EMR
The EMR communication mode can be used in the digital mode. In the EMR
mode, no call sign setting is necessary.
When an EMR mode signal is received, the audio (voice) will be heard at
the specified level even if the volume setting level is set to minimum level, or
digital call sign/digital code squelch is in use.
• OFF: Turns the function OFF.
• ON: Turns the function ON.
“EMR ” appears on the display.
NOTE:
The EMR function is automatically turned OFF when transceiver is
turned OFF.