MENU SCREEN
16-18
■
Scan items
Pause Timer
(Default: 10sec)
Scan > Pause Timer
Select the scan Pause time. When receiving a signal, the scan pauses for the
scan Pause timer Time.
•
2 to 20sec: When a signal is received, the scan pauses for 2 to 20 seconds
(set in 2 seconds steps).
•
HOLD:
When receiving a signal, the scan pauses until it disappears.
Resume Timer
(Default: 2sec)
Scan > Resume Timer
Select the scan Resume Timer time.
When a received signal disappears, the scan resumes according to the scan
Resume Timer setting.
• 0sec:
The scan resumes immediately after the signal disappears.
• 1 to 5sec: The scan resumes 1 to 5 seconds after the signal disappears.
• HOLD:
The scan remains paused for the Pause Timer setting, even if
the signal disappears.
NOTE:
Rotate [DIAL] to resume the scan.
The Resume Timer must be set shorter than the Pause Timer, otherwise
this timer does not work properly.
Temporary Skip Timer
(Default: 5min)
Scan > Temporary Skip Timer
Set the Temporary Skip Timer to 5, 10 or 15 minutes.
When the time is set, the specified frequencies are skipped for this set period
during a scan.