5 - 5
TX
SPURIOUS
([M1EURO V]
only)
ADJUSTMENT
ADJUSTMENT
ADJUSTMENT CONDITION
MEASUREMENT
VALUE
POINT
UNIT
LOCATION
UNIT
ADJUST
1 • Operating channel : ch 16
• [H/L] switch
: High
• No signal apply to the [MIC] jack.
• Transmitting
Top
panel
Connect the spec-
trum analyzer to the
antenna connector
through the attenua-
tor.
High-harmonics com-
ponents are minimum
value.
RF
L15
5-4 TRIMMER ADJUSTMENT
1
2
• Operating channel : ch 16
• [H/L] switch
: High
• Connect the audio generator to the
[MIC] jack and set as:
1.0 kHz/40 mV rms.
• Set the FM deviation meter as:
HPF
: OFF
LPF
: 20 kHz
De-emphasis
: OFF
Detector
: (P–P)/2
• Set the cursol to “ATIS” on the adjust-
ment program and push [ENTER] key.
• Transmitting
• Set the cursol to “ATIS” on the adjust-
ment program and push [ENTER] key.
• Transmitting
ATIS
MODULATION
([FRG] only)
Top
panel
Connect the FM deviation meter
to the antenna connector
through the attenuator.
±1.3 kHz (1300 Hz)
±2.1 kHz (2100 Hz)
ADJUSTMENT
ADJUSTMENT CONDITION
MEASUREMENT
VALUE
UNIT
LOCATION
5-5 ATIS ADJUSTMENT
Select an operation using [
↑
] / [
↓
] keys, then set specified value using [
←
] / [
→
] keys on the connected computer keyboard.