![Icom IC-FR5300 Instruction Manual Download Page 11](http://html1.mh-extra.com/html/icom/ic-fr5300/ic-fr5300_instruction-manual_3625464011.webp)
6
2
INSTALLATION AND CONNECTIONS
n
Power supply connection
Make sure the repeater’s power is turned OFF when
connecting a DC power cable.
R
WARNING! NEVER
apply more than 16 V DC to
the DC power receptacle on the repeater rear panel.
This could cause a fire or damage the repeater.
n
Mounting the repeater
D
Using the supplied handles
The supplied handles are used when mounting the re-
peater into a 19 inch rack. The handles are installed on
the repeater’s front panel.
q
Attach the supplied handles to both sides of the re-
peater’s front panel with the spacers, then tighten
the screws as shown below.
P0
P1
P2
P3
P4
Handle
Spacer
Screw
w
The completed installation should look like the illus-
tration below.
P0
P1
P2
P3
P4
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
n
Fuse replacement
If a fuse blows, or the repeater stops functioning, find
the source of the problem, repair it and then replace
the damaged fuse with a new rated one.
CAUTION: DO NOT
replace the fuse with the DC
power cable connected to the repeater. Disconnect
the cable to prevent electric shock and/or equip-
ment damage.
D
Line fuse replacement
Fuse rating: 20 A
USE
only a 20 A fuse.
Fuse rating: 1 A
USE
only a 1 A fuse.