![Icom IC-F5020 Series Insrtuction Manual Download Page 16](http://html2.mh-extra.com/html/icom/ic-f5020-series/ic-f5020-series_insrtuction-manual_4272806016.webp)
12
2
BASIC OPERATION
■
Stun function
When the specified ID, set as a stun ID or kill ID, is received,
the stun function is activated.
When the stun ID is received, the transceiver becomes
unusable. Entering of the password (p. 7) or receiving a
specified ID, set as a revive ID, is necessary to operate the
transceiver again in this case.
When the kill ID is received, the transceiver switches to
the cloning required condition. Cloning the transceiver is
necessary to operate the transceiver again in this case.
Stun function is also available with the MDC 1200 signaling
system. (p. 13)
■
Priority A channel selection
When one of the following operations is performed, the trans-
ceiver selects the Priority A channel automatically.
• Turning the power ON
The Priority A channel is selected each time the transceiver
power is turned ON.
• Off hook.
The Priority A channel is selected when the microphone is
took off from its hanger.