13
3
BASIC OPERATION
3
■
User Set mode
If the transceiver has [User Set Mode] assigned to it, you can
“customize” the transceiver operation to suit your preferences
and operating style.
Entering the User Set mode:
q
Push and hold [User Set Mode] for 1 sec. to enter the User
Set mode.
w
Push [User Set Mode] momentarily to select the appropri-
ate item.
Then push [CH Up] or [CH Down] to set the desired level/
condition.
•
In the User Set mode, the selectable items are preset by your
dealer. The presetable items are
Backlight, Beep, Beep Level,
SQL Level, Mic Gain, Battery Voltage, Signal Moni and Lone
Worker.
e
Push and hold [User Set Mode] for 1 sec. again to exit the
User Set mode.
■
Priority A channel selection
Depending on the presetting, the Priority A channel is selected
each time the transceiver power is turned ON.
■
Stun function
When the specified ID, set as a stun ID or kill ID, is received,
the stun function is activated.
When the stun ID is received, the transceiver becomes unus
-
able. Entering of the password (p. 9) or receiving a specified
ID, set as a revive ID, is necessary to operate the transceiver
again in this case.
When the kill ID is received, the transceiver switches to the
cloning required condition. Cloning the transceiver is neces-
sary to operate the transceiver again in this case.
Stun function is also available with the MDC 1200 signaling
system. (p. 15)
■
Scrambler function
The voice scrambler function provides private communication
between stations. The optional Rolling or Non-rolling type can
be available.
q
Push [Scrambler] to turn the scrambler function ON.
• “
” appears.
w
Push [Scrambler] again to turn the scrambler function
OFF.
• “
” disappears.