Repeater tone/tone squelch frequency settings
Command: 1B 00, 1B 01
100Hz digit: 0
~
2
10 Hz digit: 0
~
9
1 Hz digit: 0
~
9
0.1 Hz digit: 0
~
9
Fixed digit: 0*
Fixed digit: 0*
q
*
0
0
X
X
X
w
e
X
*Not necessary when setting a frequency.
D
Command formats (Continued)
•
DTCS code and polarity setting
Command: 1B 02
0 (fixed)
First digit: 0
~ 7
Second digit: 0
~ 7
Third digit: 0
~ 7
Receive polarity: 0=Normal
1=Reverse
Transmit polarity: 0=Normal
1=Reverse
q
X
X
0
X
X
w
e
X
•
DV
Digital code squelch setting
Command: 1B 07
First digit: 0
~ 9
Second digit: 0
~ 9
q
X
X
•
DV MY call sign setting
Command: 1F 00
Set your own call sign and note of up to 12 characters.
See “Character’s code of the call sign.”
X X
X X X X X X X X X X
o
~
!2
q
~
i
∙∙∙∙∙∙∙∙
q
~
i
: Your own call sign setting (8 characters)
o
~
!2
: Note setting (4 characters)
•
DV TX call signs setting
(24 characters)
Command: 1F 01
Set “UR,” “R1” and “R2” call signs of 8 characters
(fixed).
See “Character’s code of the call sign.”
X X
∙∙∙∙∙∙∙∙
X X
X X X X
X X X X
∙∙∙∙∙∙∙∙
!7
~
@4
o
~
!6
q
~
i
∙∙∙∙∙∙∙∙
q
~
i
: UR (Destination) call sign setting
(8 characters)
o
~
!6
: R1 (Access/Area repeater) call sign setting
(8 characters)
!7
~
@4
: R2 (Link/Gateway repeater) call sign setting
(8 characters)
Character’s code of the call sign
Character
ASCII code
0 ~ 9
30 ~ 39
A ~ Z
41 ~ 5A
(Space)
20
/
2F
•
DV TX message setting
Command: 1F 02
Set the transmit message of up to 20 characters.
“FF” stops sending or reading messages.
Character ASCII code Character ASCII code
A ~ Z
41 ~ 5A
a ~ z
61 ~ 7A
0 ~ 9
30 ~ 39
Space
20
!
21
#
23
$
24
%
25
&
26
\
5C
?
3F
"
22
’
27
`
60
^
5E
+
2B
–
2D
*
2A
/
2F
.
2E
,
2C
:
3A
;
3B
=
3D
<
3C
>
3E
(
28
)
29
[
5B
]
5D
{
7B
}
7D
¦
7C
_
5F
¯
7E
@
40
Remote control
19