15-9
15
SET MODE
• MIC,ACC-B: Use the signal from [MIC] and
[B ACC1] (pin 4).
• ACC-A,ACC–B:
Use the signal from [A ACC1]
and [B ACC1] (pin 4).
• MIC,ACC-A,ACC–B:
Use the signal from [MIC], [A
ACC1] and [B ACC1] (pin 4).
• USB: Use the signal from [USB].
• S/P DIF:
Use the signal from [S/P DIF].
• LAN: Use the signal from [LAN].
DATA3 MOD
(Default:
ACC-A,ACC-B
)
Selects the connector(s) to input the modulation signal
when the data 3 mode (D3) is ON.
• MIC: Use the signals from [MIC].
• ACC-A: Use the signal from [A ACC1]
(pin 4).
• ACC-B: Use the signal from [B ACC1]
(pin 4).
• MIC,ACC-A: Use the signal from [MIC] and
[A ACC1] (pin 4).
• MIC,ACC-B: Use the signal from [MIC] and
[B ACC1] (pin 4).
• ACC-A,ACC–B: Use the signal from [A ACC1]
and [B ACC1] (pin 4).
• MIC,ACC-A,ACC–B:
Use the signal from [MIC], [A
ACC1] and [B ACC1] (pin 4).
• USB: Use the signal from [USB].
• S/P DIF:
Use the signal from [S/P DIF].
• LAN: Use the signal from [LAN].
ACC-A BAND Voltage Output
(Default:
TX
)
Selects the operating band voltage output from [A
ACC2] (pin 4).
• MAIN: Outputs the band signal displayed on the Main
band.
• SUB: Outputs the band signal displayed on the Sub
band.
• TX: Outputs the band signal, that can be transmit
-
ted.
ACC-B BAND Voltage Output
(Default:
TX
)
Selects the operating band voltage output from [B
ACC2] (pin 4).
• MAIN: Outputs the band signal displayed on the Main
band.
• SUB: Outputs the band signal displayed on the Sub
band.
• TX: Outputs the band signal, that can be transmit
-
ted.
SEND Relay Type
(Default:
MOS-FET
)
Selects the switching relay type for [RELAY].
Be careful to select the suitable relay type, especially
when connecting a non-Icom linear amplifier.
• Reed: Use a mechanical relay.
(16 V DC/0.5 A maximum)
• MOS-FET: Use a semiconductor relay.
(200 mA/250 V maximum)
External Meter Output (M)
(Default: Auto)
Selects the parameter (Main readout) to output to an
external meter.
• Auto: Outputs the receiving signal strength lev
-
el during receive, and outputs the select-
ed level (selected with [METER]), during
transmit.
• S(MAIN): Outputs the receiving signal strength lev
-
el during receive.
• Po: Outputs the transmitting power level dur
-
ing transmit.
• SWR: Outputs the VSWR level during transmit.
• ALC: Outputs the ALC level during transmit.
• COMP: Outputs the compression level during
transmit.
• V
d
: Outputs the drain voltage of the final am-
plifier MOS-FETs.
• I
d
: Outputs the drain current of the final am-
plifier MOS-FETs.
External Meter Output (S)
(Default: Auto)
Selects the parameter (Sub readout) to output an ex-
ternal meter.
• Auto: Outputs the receiving signal strength lev
-
el during receive, and outputs the select-
ed level (selected with [METER]), during
transmit.
• S(SUB): Outputs the receiving signal strength lev
-
el during receive.
• Po: Outputs the transmitting power level dur
-
ing transmit.
• SWR: Outputs the VSWR level during transmit.
• ALC: Outputs the ALC level during transmit.
• COMP: Outputs the compression level during
transmit.
• V
d
: Outputs the drain voltage of the final am-
plifier MOS-FETs.
• I
d
: Outputs the drain current of the final am-
plifier MOS-FETs.
■
ACC set screen (continued)