![Icom IC-7100 Advanced Instructions Download Page 105](http://html.mh-extra.com/html/icom/ic-7100/ic-7100_advanced-instructions_611491105.webp)
5
FUNCTIONS FOR RECEIVE
5-14
Simple Band Scope
The Band Scope function allows you to visually check
the location and strength of signals around a specified
frequency.
The IC-7100’s Band Scope function can be used in any
operating mode and any frequency band.
INDICATOR
DESCRIPTION
Sweep icon
While the band scope is sweeping, “
u
” is displayed; while stopped, “
” is displayed.
Received audio is not heard from the speaker while the band scope is sweeping.
Band scope
display
Displays the signal location and strength in relation to the center (displayed) frequency. Signal
strength is relative to the S-meter level, S1 to S9+30 dB, with each vertical dot in the band scope
indicators 1 to 15 dots. B30 dB to +60 dB are also displayed by 15 dots. Signal activity is
measured ±30 steps from the center frequency, with each step equal to the selected sweep step.
Frequency
display mark
After a sweep, displays the relative position of the reference frequency. When the reference
frequency is outside of the sweep range, “ ” or “ ” blinks. After changing the frequency, touch
[RCL](
D
) for 1 second to automatically return to the center frequency.
Sweep step
display
Displays the selected sweep step. 0.5, 1, 2, 5, 10, 20 and 25 kHz are selectable. Each dot of the
band scope display is equal to the selected sweep step.
The band scope measures receive signal location and
strength over a specified range on either side of a selected
frequency, in either the VFO or memory modes.
Rotate the Dial to select a frequency.
q
Push
w
MENU
(
C
) one or more times to select the
“M-3” screen (M-3 menu).
Touch [SCOPE](
e
D
) to display the “SCOPE” screen
(Band Scope).
• Automatically starts sweeping with the previously select
-
ed sweeping step.
• During a sweep, received signals cannot be heard.
Touch [STEP](
r
D
) one or more times to select the
desired sweep step.
•
0.5, 1, 2, 5, 10, 20 and 25 kHz are selectable.
Touch [
t
](
D
) to start sweeping, then automati-
cally stop after sweeping.
• Touch [
](
D
) for 1 second to start continuous sweep-
ing. In this case, touch [
u
](
D
) to stop the sweeping.
• During a sweep, “
u
” is displayed and received signals
cannot be heard.
• If there is a lot of signal noise, turn OFF the Preamplifier
to reduce the signal input level, and turn ON the Attenu-
ator to improve the readability of the band scope.
Rotate the Dial to find a signal that you wish to com-
y
municate with. If you find the signal, communicate in
the normal way.
• If you want to return to the frequency you were using
before rotating the Dial, touch [RCL](
D
) for 1 second.
• If the selected frequency is set outside of the sweep
range, “ ” or “ ” blinks.
If you want to update the band conditions while re-
u
ceiving, repeat steps
r
and
t
.
NOTE:
If you select a large sweep step, a wide frequency
range can be displayed on the band scope, but some
signals may be skipped and not displayed.
Touch [SCOPE]
Band scope display
Sweep start/stop
Sweep step selection
Sweep icon
Sweep step
display
Frequency display mark
Blinks when the reference frequency
is outside of the sweep range.
Previous view