![Icom D-STAR ID-31A; D-STAR ID-31E Advanced Instructions Download Page 286](http://html2.mh-extra.com/html/icom/d-star-id-31a-d-star-id-31e/d-star-id-31a-d-star-id-31e_advanced-instructions_3494369286.webp)
TROUBLESHOOTING
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
I
• While operating D-STAR
PROBLEM
POSSIBLE CAUSE
SOLUTION
REF.
After your call, the repeater
does not transmit a reply.
• The repeater setting is wrong.
• The transceiver is out of the repeater
range, or your transmission does not
reach the repeater.
• Set the correct repeater.
• Correct the repeater frequency, fre
-
quency offset, or duplex setting.
• Try to access another repeater.
After your call, the repeater
replies ‘UR?’ and its call
sign.
• The call was successfully sent, but no
station’s signal was immediately re
-
ceived.
• Wait for a while, and try it again.
After your call, the repeater
replies ‘RX’ or ‘RPT?’ and
the call sign of its gateway
repeater.
• MY call sign has not been set.
• Your own call sign has not been reg
-
istered to the D-STAR Server. Or it’s
wrong.
• Your calling station call sign has not
been registered to the D-STAR Server.
Or it’s wrong.
• Set the MY call sign.
• Register your own call sign to the D-
STAR Server. Or confirm the registra
-
tion of your own call sign.
• Ask the server’s administrator about
your calling station’s call sign.
—
After your call, the repeater
replies ‘RPT?’ and call sign
of the called repeater.
• The D-STAR cannot connect to the
called repeater, or
it’s busy.
• Wait for a while, and try it again.
After your call, the repeater
replies ‘RPT?’ and its call
sign.
• The call sign of the called repeater is
wrong.
• Correctly set the called repeater call
sign.
Even holding down
, the
DR mode will not appear.
• The repeater list has been cleared.
• Reprogram the repeater list using the
CS-31 cloning software.
• Reprogram the repeater list with the
transceiver.
pp. 11-11 to
11-15, 12-9
p. 4-19
Even holding down
, the
received call sign will not set
to the operating call sign.
• The call sign has not been correctly re
-
ceived.
• Try it again, after the transceiver has
again received its call sign.
—
The repeater does not ac
-
cept your gateway call.
• Your call sign has not been registered to
the D-STAR system.
•
Ask your desired repeater’s adminis
-
trator about call sign registration.
—
The simplex operation can
-
not be made in the DR
mode.
• A call sign is programmed in “CALL SIGN”
of the Repeater list.
• Duplex mode (DUP+, DUP–) is set.
• A repeater frequency is programmed.
• Delete the Call sign in “CALL SIGN”
setting of the Repeater list.
• Select “OFF” in “DUP” setting of the
repeater list.
•
Program a simplex frequency.
p. 24 in
the Printed
manual
■
Troubleshooting
The following chart is designed to help you correct
problems which are not equipment malfunctions.
If you are unable to locate the cause of a problem
or solve it through the use of this chart, contact your
nearest Icom Dealer or Service Center.
Previous view