PIVOT-IR USER MANUAL
53
11-6 Memory card error
•
Format the internal memory
•
Perform a factory reset
11-7 Temperature readings are incorrect
•
Turn off the device; then, turn it back on
•
To ensure the accuracy of temperature measurement, it is recommended
to wait for 5 to 10 minutes after turning on the thermal imager and before
attempting to take temperature measurements.
•
Ensure the correct temperature range is selected:
◦
The default temperature range is -20 °C to 150 °C (-4 °F to 302 °F)
◦
When measuring high temperature objects ensure the temperature
range is set to the 100 °C to 500 °C (212 °F to 932 °F) range
•
Ensure device is at proper height
•
Adjust the distance to the target
•
Adjust
the distance setting
•
Adjust
the
emissivity
setting
•
Adjust the ambient temperature
setting
•
Perform a manual NUC operation
•
Send the device in for recalibration