GC-76/GC-106 GAS LEAK DETECTION CORE USER MANUAL
10
SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE
4.
Technical Specifications
GC-76
Gases Detected
Methane, Nitrous Oxide, Sulfur Dioxide, Phenol,
Cyclopentanone, Hydroxycarbonyl, R13, R13B1, R123,
R125, R134A, R417A, R422A, R508A,
Pixel Resolution
640 x 512
Accuracy
± 3°C (± 5.4°F) or ± 3%
Temperature Range
-20°C to 120°C (-4°F to 248°F)
Operation Range
-20°C to 50°C (-4°F to 122°F)
Storage Range
-45°C to 85°C (49°F to 185°F)
Detector Type
UFPA (VOx)
Pixel Pitch
12 μm
Spectral Band
7 μm to 8.5 μm
Frame Rate
25 Hz
Humidity
5% to 95%, non-condensing
Pixel Operability
> 99 %
Shock
80 G
Vibration
6.06 G
Dimensions (without lens)
26 mm x 26 mm x 22m (L x W x D ± 0.5 mm)
(1.02” x 1.02” (L x W x H ± 0.02”))
1
Weight (without lens)
21 g (0.74 oz)
Power
4V ~ 6V DC, < 1.3W
2
Power Protection
Over-voltage; under-voltage; reverse polarity
Interface
RS-232; UART (3.3 V)
Expansion Board
Call for options
Video
Analog: 1 channel PAL or NTSC
3
Digital: BT.656; 8-bit or 14-bit LVCMOS; LVDS
4
Video Mirror
Horizontal; Vertical; Diagonal
5
Image Polarity
White hot or black hot
Image Processing
Digital enhancement; Imaging denoising
5
Reticle
R
eveal; Hidden; Shift
5
Brightness
Adjustable
Zoom
1.0X ~ 8.0X continuous
5
Palette support
5