THIS DEVICE IS INTENDED FOR ADJUNCTIVE USE WITH OTHER CLINICAL DIAGNOSTIC 

PROCEDURES 

TO  MEASURE  HUMAN  BODY  TEMPERATURE  VIA  NON-CONTACT  SKIN 

MEASUREMENTS VISUALIZED FROM THE HUMAN FACE. NOT MEANT FOR STANDALONE 

CLINICAL DIAGNOSTIC PROCEDURES OR TO TREAT OR DIAGNOSE PATIENTS.

For more information, contact us: (409) 861-0788 | [email protected] | www.infraredcameras.com

Medical

Medical

Edit Text

Outlines

Summary of Contents for FM 384 P Series

Page 1: ...ort Control THIS DEVICE IS INTENDED FOR ADJUNCTIVE USE WITH OTHER CLINICAL DIAGNOSTIC PROCEDURES TO MEASURE HUMAN BODY TEMPERATURE VIA NON CONTACT SKIN MEASUREMENTS VISUALIZED FROM THE HUMAN FACE NOT MEANT FOR STANDALONE CLINICAL DIAGNOSTIC PROCEDURES OR TO TREAT OR DIAGNOSE PATIENTS For more information contact us 409 861 0788 sales infraredcameras com www infraredcameras com Medical Medical Edit...

Page 2: ...TE BUT ARE PRESENTED WITHOUT WARRANTY OF ANY KIND NOTWITHSTANDING ANY OTHER WARRANTY HEREIN ALL DOCUMENT FILES AND SOFTWARE ARE PROVIDED AS IS WITH ALL FAULTS ICI DISCLAIMS ALL WARRANTIES EXPRESSED OR IMPLIED INCLUDING WITHOUT LIMITATION THOSE OF MERCHANTABILITY FITNESS FOR A PARTICULAR PURPOSE AND NONINFRINGEMENT OR ARISING FROM A COURSE OF DEALING USAGE OR TRADE PRACTICE THE SOFTWARE LICENSE AND...

Page 3: ...ty Information 3 Intended Use 4 Technical Specifications 5 Structure 6 Package Contents 7 Installation Instructions 8 Computer Setup 9 Cleaning and Maintenance 10 Site and System Validation Checklist 11 Troubleshooting 12 About ICI Contents 4 4 4 5 6 7 8 13 15 16 17 21 ...

Page 4: ... to prevent dangerous actions such as the device being hit by external force or falling from heights During transportation and storage the original packaging box must be used Prior to start of the device make sure that the power supply is properly connected If the power supply is connected incorrectly the device may be damaged Do not place any objects on the power cord and do not place the device ...

Page 5: ...6 F to 113 F Operation Range 30 C to 50 C 22 F to 122 F Storage Range 40 C to 70 C 40 F to 158 F Humidity 95 Accuracy 0 2 C 0 36 F Pixel Operability 99 Shock Vibration 25 G 2G Dimensions without lens 236 mm x 130 mm x 80 mm L x W x H 0 5 mm 9 29 x 5 12 x 3 15 L x W x H 0 02 Power 12V DC 1 A 30 W Weight without lens 850 g 1 87 lbs Interface USB 2 0 Video H 264 IR and UVC NV12 visible Emissivity Cor...

Page 6: ...FM 384 P SERIES IR CAMERA USER MANUAL 6 5 2 Definitions of Housing Interface 1 2 1 Speaker reserved 2 USB interface 3 Barrel connector 3 5 Structure 5 1 Appearance ...

Page 7: ...UAL 7 6 Package Contents Power Extension Cable FM Series IR Camera Power Adapter USB Cable Software USB Drive Temperature Reference AC Power Cord ENSURE ALL SYSTEM EQUIPMENT AND COMPONENT ITEMS ARE PRESENT BEFORE BEGINNING INSTALLATION ...

Page 8: ...E AIRFLOW FROM DOORWAYS AND AIR CONDITIONING VENTILATION SYSTEMS THE SELECTED AREA SHOULD HAVE A STABLE AMBIENT TEMPERATURE BETWEEN 20 C AND 24 C 68 F TO 75 2 F AND RELATIVE HUMIDITY RANGE FROM 10 TO 50 B Mount the Temperature Reference to a tripod using the 20 mount Plug power cord into Temperature Reference A ...

Page 9: ...ipod using the 20 mount D C Plug power cord into a 110 120V electrical outlet MAKE SURE TRIPODS DO NOT BLOCK THE DIRECT PATH OF PERSON S TO BE IMAGED TO ENSURE THE EQUIPMENT WILL NOT BE MOVED OR KNOCKED DOWN USING A DIVIDING BARRIER WILL HELP KEEP TRIPODS SEPARATE FROM THE PATH ...

Page 10: ...he barrel cable attached to the FM Series IR Camera Plug the power cord into the barrel end of the power extension cable IF EXTRA LENGTH IS NOT NEEDED LEAVE OUT THE POWER EXTENSION CABLE AND INSTEAD PLUG THE JACK END OF THE POWER CORD INTO THE BARREL CABLE ATTACHED TO THE FM SERIES IR CAMERA ENSURE THE CAMERA LENS AND TEMPERATURE REFERENCE SOURCE ARE FACING EACH OTHER ON PARALLEL PLANES MAKE SURE ...

Page 11: ...WILL PROVIDE THE MOST ACCURATE SKIN TEMPERATURE MEASUREMENTS SOFTWARE ARRIVES INSTALLED ON COMPUTERS AND TABLETS PURCHASED FROM ICI AS COMPLETE SYSTEMS AND IT WILL LAUNCH AUTOMATICALLY ON STARTUP AFTER THE SOFTWARE LAUNCHES THE USER SHOULD ENSURE THE TARGET ZONE IS IN VIEW OF THE CAMERA AND THE TEMPERATURE REFERENCE SOURCE IS POSITIONED OFF CENTER TO KEEP THE PERSON BEING IMAGED AS CENTERED AS POS...

Page 12: ...al of glasses headwear and masks Read the current government guidance regarding the use of telethermographic systems for skin temperature measurements Additional information can be found by reading IEC 80601 2 59 2017 Medical electrical equipment Part 2 59 Particular requirements for the basic safety and essential performance of screening thermographs for human febrile temperature screening and IS...

Page 13: ...is no need to set a gateway as this is a direct connection from the computer to the cameras with no router Be sure the static IP address is set by doing the following 1 Click on Windows icon 2 Click on Settings 3 Click on Network and Internet 4 Click on Ethernet 5 Click on Change Adapter Options 6 Right click on Ethernet and choose properties 7 Double click on Internet Protocol Version 4 TCP IPV4 ...

Page 14: ...tions provided by Infrared Cameras Inc only Do not install software from unknown entities Don t connect unknown hardware devices e g USB devices external hard drives etc to the system computer If you suspect that the system computer has been infected with malware contact your organization s IT department or Infrared Cameras Inc for further assistance If your device does not require usage of the e ...

Page 15: ... middle to the edge paying attention to not crack the lens or use too much liquid If the lens is still not clean replace the cloth and repeat the wiping process 9 Cleaning and Maintenance 9 2 Disinfecting the Camera Surface Do not use corrosive cleaning solutions on the optical glass components It is recommended to disinfect the camera surface regularly with a non corrosive sanitizing product Foll...

Page 16: ...rflow HVAC vents intakes Any radiant energy from electrical sources Direct or indirect lighting on individual being screened Room temperature is 20 C 24 C 68 F 75 F Relative humidity is within 10 50 10 2 The Screening Background Placement is parallel and perpendicular to screening camera At a distance of 12 feet Consists of a non IR reflective homogeneous background Minimum size is 10 x 8 White to...

Page 17: ... footprints The distance is unique to each screening system Ensure the line of sight from the temperature reference source to the camera is never blocked by an individual entering or leaving the point of measurement The secondary screening area should be setup near the screening area 10 4 Typical traffic flow illustration 10 5 IR Camera Placement Level on tripod or other suitable support Perpendic...

Page 18: ...ipod or other stable stand in front of background and positioned for visibility within the frame of the image Temperature is set at 35 C 95 F or 37 C 98 6 F Warm up time is 15 minutes 10 7 Software Set up the software according to the instructions provided Documentation can be found online on the IR Flash STM web page under the Downloads section or at this address https infraredcameras com ir flas...

Page 19: ...tween camera and subject 11 3 Temperature readings are incorrect or facial recognition is suboptimal Close and reopen software Check that software settings are correct Fixed temperature of 35 C 95 F or 37 C 98 6 F depending on temperature reference source Temperature reference source has crosshair over it Remove masks glasses Camera is proper distance from person Camera is at proper height Tempera...

Page 20: ...FM 384 P SERIES IR CAMERA USER MANUAL 20 Plain background Try newer version of IR Flash STM software ...

Page 21: ... Institute In addition to providing custom germanium silica and sapphire optics we also build windows for enclosures as well as custom pan and tilt units We can even provide customizable explosion proof systems Our knowledge and experience stems from years of using infrared imaging and temperature measurement instruments to provide solutions to managers engineers scientists inspectors and operator...