Tip 1:
Error Code 16 Potential Causes
Water level sensor detects
water at the high-level
probe at end of freeze cycle.
Water:
•
Is the water level sensor faulty or in need of cleaning?
•
Is the water inlet valve stuck open or allowing water to
bleed through it.
•
Faulty PCB.