Page 1: ...SERVICE MANUAL FD HD 1 SERVICE MANUAL FD HD SERIES ICE CUBE MAKERS ICE TECH FD HD 215 ICE TECH FD HD 415...

Page 2: ...connection 10 3 PRIOR CHECKING AND START UP 11 3 1 Prior checking 11 3 2 Start Up 11 4 SEQUENCE OF OPERATION 12 4 1 Initial Start up 13 4 2 Control Board 15 4 3 Alarms 16 4 4 Safety pressure 17 4 5 Lo...

Page 3: ...SERVICE MANUAL FD HD 3 6 1 Dimensions voltaje 24 6 2 Production Charts 26 7 USER TROUBLESHOOTING GUIDE 27 7 1 Modular models 27 8 WIRING DIAGRAMS 28 8 1 FD HD single phase 28 8 2 FD HD three phase 29...

Page 4: ...It is extremely dangerous to modify or intend to modify this machine and will void warranty This machine should not be used by children or handicapped without the proper supervision and monitoring Th...

Page 5: ...ument or freight document Always state the machine number and model This number is printed on three locations 1 Packing On the outside it contains a label with the serial number 2 Exterior of the unit...

Page 6: ...wo lateral louvers In the case it is not possible to respect the minimum distances recommended see the picture in point 3 3 for these machines we recommend to install a water cooled unit The location...

Page 7: ...ing the instructions contained in this manual The resistance and stability of the container machine s assembly should be verified as well as the fastening elements Follow bin manufacturer instructions...

Page 8: ...SERVICE MANUAL FD HD 8 CONNECTION DIAGRAM The location must allow enough clearance for water drain and electrical connections in the rear of the ice machine MODULAR MODELS...

Page 9: ...installing a water filter system refer to the installation instructions supplied with the filter system Use a flexible food grade hose Pressure should be between 0 7 and 6 bar 10 and 85 psi If pressur...

Page 10: ...cement should be performed by qualified technical service only The machine should be places in such a way as to allow a minimum space between the back and the wall to allow an easy access and without...

Page 11: ...er than 6bar 85psi install a pressure regulator 3 2 Start Up Once the installation instructions are followed ventilation site conditions temperatures water quality etc proceed as follows 1 Open the wa...

Page 12: ...OF OPERATION Initial Start up The pump and the drain electrovalve are energized during 30 seconds to empty the water tray preventing the scale build up in water Then the pump and the drain electrovalv...

Page 13: ...tputs switched off when machine is connected to power supply when the switch is turned to the ICE position after a stop due to full storage During start up time t4 the pump B and the drain valve EP ar...

Page 14: ...ne will be stopped due to full storage all outputs are switched off LED LE3 continuously switched on When the curtain MC is closed again the initial start up phase will be re initiated time descriptio...

Page 15: ...y contactor 5 B pump 5 EW Water inlet valve 5 GC Hot gas valve 5 EP Drain valve 5 SL Free 5 Symbol Description ICE Ice position switch Switch for 3 positions Ice 0 wash WASH Wash position switch P Saf...

Page 16: ...escription LO 1 6 6 orange LEDs for each output LI 1 7 7 green LEDs for each input LE 1 4 4 red LEDs for status alarm flashing stand by ice full wash 4 3 Alarms They detect operational malfunctions Th...

Page 17: ...utomatic reset The machine will continue at the position where it was Signalling Flashing in the four LEDs 4 5 Long operation If the operation launching time is longer than t5 time without activation...

Page 18: ...ne The upper machine operates normally except when the lower machine is stopped due to full storage full at this moment the upper machine will also stop and pass over to the same status full When the...

Page 19: ...the evaporator Damage may result 3 Prepare a solution of an appropriate product for the cleaning of ice machines lime Do not use hydrochloric acid We recommend the use of any NSF approved scale remova...

Page 20: ...ill it and then set the ice wash switch to the OFF position 6 Disconnect power and close water supply 7 Mix a cleaning solution 8 Remove shield and water tray 9 Clean the metal surfaces of the thickne...

Page 21: ...nt panel applying liberally the sanitizer solution using a cloth or sponge 14 Return the water tray and shield to their normal positions 15 Connect power and water supplies 16 To start a sanitation cl...

Page 22: ...er soft brush or low pressure air Clean from top to bottom not side to side Be careful not to bend the condenser fins WATER CONDENSER The water condenser may require cleaning due to scale build up The...

Page 23: ...soap and water Wipe dry with a clean soft cloth A commercial grade stainless steel cleaner polish can be used as necessary 5 4 Water leakage checking This must be done whenever maintenance is carried...

Page 24: ...Water 762 620 500 330 635 625 ICE TECH FD HD 215 W1H Water 762 620 500 330 635 625 ICE TECH FD HD 215 A2F Air 762 620 500 330 635 625 ICE TECH FD HD 215 A2H Air 762 620 500 330 635 625 ICE TECH FD HD...

Page 25: ...50Hz 1Ph 1 840 9 15 25 700 FD HD 215 A2H 220V 50Hz 1Ph 1 2 840 9 15 25 700 FD HD 215 W2F 220V 50Hz 1Ph 1 840 9 15 25 700 FD HD 215 W2H 220V 50Hz 1Ph 1 2 840 9 15 25 700 FD HD 415 A2F 220V 50Hz 1Ph 1...

Page 26: ...FD HD 215 A1H Lb 24h AGUA C AIRE C 10 15 20 25 10 204 200 190 180 20 190 185 174 165 32 158 150 141 130 37 135 124 112 100 FD HD 415 A2F Lb 24h AGUA C AIRE C 10 15 20 25 10 448 435 420 395 20 432 420...

Page 27: ...robe too low Move up steel rod beside pump Defective drain valve check drain leak during ice stage Disassemble and clean Shield splash leaks Check shield position Water overflows tray Level probe too...

Page 28: ...phase COMPONENTS H Safety pressostat N Curtain sensor I Ice Wash 3 positions S Compressor R Fan motor J Condensation pressostat water condenser B Pump P Water valve Q Hot gas valve D Drain valve NW W...

Page 29: ...ree phase COMPONENTS H Safety pressostat N Curtain sensor I Ice Wash 3 positions S Compressor R Fan motor J Condensation pressostat only air B Pump P Water valve Q Hot gas valve D Drain valve NW Water...