background image

3

Air path for exhaust

and fresh air intake

must be unrestricted!

Recirculation between

fresh air intake and

exhaust air must be

prevented.

FIG. #1 Ventilation

IN

OUT

Model 85

IN

OUT

Model 84

MOUNTING

Required Cabinet Opening:
Model 84: 14 3/8" W x 18 1/2"H

Model 85: 14 3/8" W x 24 5/8"H
WARNING:  If rubber feet are removed from the
bottom of 85 series units, the mounting screws
must be reinstalled into the bottom of the cabinet
to avoid damage to components mounted to the
base pan.

If unit is to be built-in, 3/4" (2cm) or more must be
allowed behind the unit for water line and plug
clearance for proper operation.  Built-in units are
designed for zero clearance at the top and each side
of the unit.  Fan-forced condenser cooling is used.
This requires air circulation through lower section of
unit (see Fig. #1).  If  Icer-ette is to be installed behind
closed doors, contact Raritan Technical Support.

CAUTION:  Any restriction of airflow or
ventilation will disrupt normal operation of the
unit, resulting in damage to components and
voids warranty.

Unit must sit on a secure level surface. Mounting
flange must NOT be used to support the unit's
weight.

When installing the unit it should be noted that some
servicing requires access to the rear of the unit and
that 

the unit must be readily removable

 should

servicing be necessary.

When mounting unit within cabinetry, make sure
that the door has the desired range of motion.  All
doors are hinged on the right (facing the unit) but
may be reversed in the field.

PLUMBING

A minimum of 22 P.S.I. (152kPa) is required for
proper operation of the water valve (see #26, page 4).

When plumbing Icer-ette, 18" (45cm) of water line
extends from the back with a 1/4" plastic female
compression fitting.  Drains are not required; just a
water supply.

WIRING

WARNING:  HAZARD OF ELECTRIC SHOCK
- Never use extension cords or plug adapters to
power unit.  Never remove the ground prong
from the plug.
Power Requirements:  

120 volts 60 HZ AC

(alternating current); a three-wire cord with grounded
plug is supplied, 

OR:   

240 volts 50 HZ AC

(alternating current), supplied with Euro-plug.

INSTALLATION

BOTTOM FLANGE INSTALALTION

MODEL 85/84B

1. Loosen top two grille

screws

2. Remove bottom two

grille screws

3. Place bottom trim

flange between grille
and cabinet.

4. Align holes and install

bottom grille screws

MODEL 85E

Once unit is installed in cabinet

1. Attach trim spacer to bottom flange

2. Slide bottom flange in place.

3. Secure with 2 screws.

Summary of Contents for 84

Page 1: ...g gasoline tanks or in areas in which ignition protected equipment is required INTRODUCTION Model 84 and 85 Icer ettes are CFC Free automatic icemakers designed and manufactured especially for the mar...

Page 2: ...hite plastic tubing and nut from bottom of solenoid valve Model 84 Disconnect the in line water supply connector behind the front grille 3 Turn power on Allow unit to run for an hour Removeanycubestha...

Page 3: ...t the unit s weight When installing the unit it should be noted that some servicing requires access to the rear of the unit and that the unit must be readily removable should servicing be necessary Wh...

Page 4: ...11 19 17 41 40 42 43 29 LINE VOLTAGE GREEN GREEN YELLOW WHITE BLUE BLACK 120 VAC BROWN 240 VAC POWER SWITCH GREEN BLACK FUSE LINKS COMPRESSOR RELAY AND OVERLOAD COMPRESSOR FAN A B 7 2 RELAY BLACK WHIT...

Page 5: ...m o t t o B 1 8 1 F 1 5 H C 1 8 1 F 1 5 H C 1 8 1 F 1 5 H C 1 8 1 F 1 5 H C 9 1 m o t t o B p o T t e S e g n i H W 3 1 M I W 3 1 M I W 3 1 M I W 3 1 M I 0 2 t e k c u B e c I 0 9 I 0 9 I 0 9 I 0 9 I...

Page 6: ...ecommended that only a qualified refrigeration technician perform service on Icer ettes Because of high voltage high pressure refrigeration and presence of water in the unit a person who is not techni...

Page 7: ...kg per day Water Supply Minimum 22 psi 152kPa Maximum 125 psi 863kPa Ice Storage Capacity up to 11 lbs 5kg Max AMP Draw 120 Volt 2 5 240 Volt 1 3 Refrigerant Charge 2 4 oz 68 grams R 134A SPECIFICATIO...

Page 8: ...ct of God 3 ANYEXPRESSWARRANTYNOTPROVIDEDHEREIN ANDANYREMEDYFORBREACHOF CONTRACT WHICH BUT FOR THIS PROVISION MIGHT ARISE BY IMPLICATION OR OPERATIONOFLAW ISHEREBYEXCLUDEDANDDISCLAIMED ALLIMPLIEDWARRA...