10
MT-AMP 1000
43
.
MOH Level Adjust
Adjust output level of MOH signal.
44.
8Ω MOH Output.
8
次
MOH output terminal for monitoring source module or AUX1~3 signal.
It is selected by (7) select switch.
45. BALANCED MOH Output
Balanced MOH output terminal for monitoring source module or AUX1~3, (600
次
, balance signal.)
It is selected by (7) select switch.
46. TEL/EMG 100V-0 input
100V input of TEL/EMG signal, it is convenient for long distance broadcasting.
47. TEL/ Emer. Input
Terminal for balanced Telephone/ Emergency signals input.
48. TEL. Level Adjust
Adjust Telephone signal input level.
49. Paging Station Terminal
RJ45 socket can be connected to callstations. It can connect up to 6 callstations.
50. Wall Control Panel Terminal
RJ 45 terminal can be connected to Wall Control Panel MT-WCP-6. When wall control panel is activated,
the remote LED will light up. Then Wall Control Panel can control the ZONE output of main unit, select
SOURCE, AUX1-3, and adjust the Master output level.
51. XLR out for Ext. Amplifier
0 dB, 600
次
, balanced XLR output terminal. It is the output of whole preamplifier stage with balanced
signal. It can be connected to Ext. Amplifier.
52. REC out
Record output RCA terminal. It is the output signal before MASTER volume control. This signal can be
connected to cassette recorder etc. to record signal of preamplifier stage.
53. POWER in
0 dB, unbalanced RCA terminal. It is for signal input of power amplifier. It can be connected to the “PRE
OUT ” RCA terminal or other signal source unit.
54. PRE out
0 dB, 600
次ㄛ
unbalanced RCA output terminal. It is the output of whole preamplifier stage
55. VOX Mute Level.
Adjust SOURCE, AUX 1 ~ 3 muting level during priority muting function is activated.