IBS Intelligent Battery System GmbH 

Seestrasse 24, CH-3600 Thun,  Schweiz 
Tel: +41 33 221 06 16 
Fax: +41 33 221 06 17 
E-Mail: [email protected]

 

 

 

IBS-USG4_en_v2.0.3.doc

 last Update 28.8.2018

   

 

 

 

 

 

 

          

1

 

 

 

 
 

 
 
 
 
 
 
 
 
 
 

Ultra Sine Inverter (US) 

Generation 4 (G4) 

User Guide 

Summary of Contents for US160

Page 1: ... Battery System GmbH Seestrasse 24 CH 3600 Thun Schweiz Tel 41 33 221 06 16 Fax 41 33 221 06 17 E Mail info ibs tech ch IBS USG4_en_v2 0 3 doc last Update 28 8 2018 1 Ultra Sine Inverter US Generation 4 G4 User Guide ...

Page 2: ... Recommended battery capacity 8 External fuse 8 Installation Steps 9 Wiring 9 Grounding 10 Connecting the consumer device 10 Connectors for device 10 Commissioning the unit 10 Connect the remote control 10 Switching on the appliance 10 Activating deactivating standby 10 Status Display 11 Status 11 Operating Modes 11 Error display 11 Troubleshooting 11 Power display 12 Assembly 13 Housing dimension...

Page 3: ...ffee machines hand held machines computers laser printers measuring instruments medical devices can be operated in most cases Applications Motorhomes Camper 4WDs Expedition Rallye Yachting Solar island installations Commercial and industrial use Energy back up for computers communications and medicine Mobile power for craftsmen Data Technologie High frequency Dual processor Galvanic separation Rem...

Page 4: ... 1 6 kW 0 7 kW S4 12 3V 24 6V 1 2 V 100 ms 3 0 kW 1 5 kW 0 6 kW Protection of deep discharge of the battery The inverter is equipped with an intelligent current dependent deep discharge circuit Switch off value 11 8V 23 6V re activation 12 3V 24 6V Immediate shutdown when battery drops below 10 5V 21 0V Performance The IBS inverters are very powerful as long as the batteries provide the necessary ...

Page 5: ...s damage to the battery the Ultra Sine inverter and the electrical installation Fuses cannot prevent damage caused by polarity reversal Such damages are not included in the warranty Inverter output cannot be connected to the public network Use US TS for automatic landline inverter switching Never insert objects through the openings and ventilation slots of the device Supplied content US160 80 40 M...

Page 6: ...6 Informations Front view US160 US80 Abb 2 Front view US160 80 US40 Abb 3 Front view US40 ...

Page 7: ...7 Rear view US160 Abb 4 US160 Rear view US80 Abb 5 US80 Rear view US40 Abb 6 US40 Rear view ...

Page 8: ...refer to the copper cross section of the cables Recommended battery capacity High loads caused by an inverter system need sufficient available battery capacity To ensure that the required application has enough energy refer to the following table for recommended battery capacities Load Capacity of 12V System Capacity of 24V System 500 W 60 Ah 2 x 30 Ah 500 W 80 Ah 2 x 40 Ah 1000 W 100 Ah 2 x 50 Ah...

Page 9: ... please consult the manual for instructions and safety instructions A main switch S1 must be provided to allow emergency disconnection of incoming shore power supply In mobile applications such as travel trailers or yachts with a possible landline the two 230V networks inverter and landline connection may only be connected via the US TS FI switch The same applies if 230V emergency generators are u...

Page 10: ...onnection cable of the remote control into the remote control plug A non crossed 8 pin RG45 cable must be used Switching on the appliance To switch the device on and off press the on off button on the front of the device or the button on the RP03 remote control Activating deactivating standby To activate or deactivate standby press the on off button on the front of the device or the button on the ...

Page 11: ...ver temperature 3 System fault fuse defective overcurrent 4 Short circuit overload Troubleshooting Error Triggered by Resetting by 1 Delayed Voltage lower than 11 8V 23 6V Or higher than 15 5V 31 0V Immediately Voltage lower than 10 5 V 21 0 V Voltage higher than 13 1V 26 2V or lower than 14 5 V 29 0 V Voltage higher than 13 1V 26 2V 2 If the temperature is too high at the heat sink f the heat sin...

Page 12: ...12 Power display The US80 and US160 have an output power indicator The number of luminous LEDs indicates the current output power Abb 9 Power display US160 left and US80 right ...

Page 13: ...13 Assembly Housing dimensions Abb 10 US160 Housing dimensions ...

Page 14: ...14 Abb 11 US80 Housing dimensions ...

Page 15: ...15 Abb 12 US40 Housing dimensions ...

Page 16: ...Abb 13 Horizontal alignment of mounting feet Abb 14 Vertical alignment of mounting feet Screw the mounting feet to the intended positions using the screws supplied Only the included screws may be used The tightening torque is 1 1 Nm ...

Page 17: ...he fan must not be obstructed so that the warm air which is generated during operation can escape unimpeded Do not install in a small enclosed space ensure air circulation Ensure that no objects dust or dirt can enter the interior of the unit through the ventilation slots or fan Avoid any contact with water moisture or rain Humidity 0 95 non condensing ...

Page 18: ...g on current and temperature 4 Observe the same safety regulations as when using the 230V public network When using the inverters an additional fuse of 150A 12V 80A 24V is recommended directly at the battery connection or circuit breaker automatic fuse Specifications Technical specifications US40 US80 US160 12V 24V 12V 24V 12V 24V Input voltage 10 5V 15 5V 21 0V 31 0V 10 5V 15 5V 21 0V 31 0V 10 5V...

Page 19: ...19 Notes ...

Page 20: ...20 ...

Page 21: ...witch on the caravan e Check the function of the residual current device RCDs FI installed in the caravan by pressing the test buttons and switch it on again Remark 1 The flexible supply line of the caravan should be completely unwound to avoid damage caused by overheating Remark 2 In case of doubt or if the supply is not available or is faulty after the above mentioned procedure has been carried ...

Page 22: ...22 ...

Page 23: ...23 ...

Page 24: ... 6 US40 Rear view 7 Abb 7 Cabling normal use 9 Abb 8 Cabling with US transferswitch 9 Abb 9 Power display US160 left and US80 right 12 Abb 10 US160 Housing dimensions 13 Abb 11 US80 Housing dimensions 14 Abb 12 US40 Housing dimensions 15 Abb 13 Horizontal alignment of mounting feet 16 Abb 14 Vertical alignment of mounting feet 16 ...