Last update:
2022-05-31
IBS
Precision Engineering • Eindhoven • NL • +31 40 290 1270
User Manual |
P7
12
Connecting to the ECL150
The ECL150 is shipped with all required connecting cables. Power and Output connecting cables are terminated
with an M12 device connector at one end and color-coded wires at the other end.
Device Connector: 4-Pin, M12, Male Power Cable PN: 6203-0400
Pin
Wire Color
Connection
1
Brown
12 to 24 VDC
Internally Connected
2
White
12 to 24 VDC
3
Blue
Power Ground
Internally Connected
4
Black
Power Ground
12.1
Sync Connections
Sync connectors are only installed when multiple systems are sold together. Connect a sync cable (Lion
Precision Part Number 6203-0820) from the SYNC OUT of one system to the SYNC IN of the other system.