7.
Start the Configuration/Setup Utility program and set configuration
parameters.
v
Set the server date and time.
v
Set the power-on password.
v
Reconfigure your server.
Temperature checkout
Proper cooling of the server is important for proper operation and server reliability.
For a typical xSeries server, you should make sure:
v
Each of the drive bays has either a drive or a filler panel installed
v
Each of the power supply bays has either a power supply or a filler panel
installed
v
The server cover is in place during normal operation
v
There is at least 50 mm (2 inches) of ventilated space at the sides of the server
and 100 mm (4 inches) at the rear of the server
v
The server cover is removed for no longer than 30 minutes while the server is
operating
v
The processor housing cover covering the processor and memory area is
removed for no longer that ten minutes while the server is operating
v
A removed hot-swap drive is replaced within two minutes of removal
v
Cables for optional adapters are routed according to the instructions provided
with the adapters (ensure that cables are not restricting air flow)
v
The fans are operating correctly and the air flow is good
v
A failed fan is replaced within 48 hours
Attention:
If using AOL/2 or system supported monitoring software, and you are receiving a
thermal alert with no fan alert, check SYSFA1 and CPUFA2, which are
unmonitored and therefore cannot generate alerts, to make certain that those fans
are connected to planar power and are functional.
If the system powers itself down, the cause maybe an overheated processor
causing a thermal trip. One of your checks should be to ensure that both system
fans and both CPU fans are connected to planar power and are functional.
In addition, ensure that the environmental specifications for the server are met. See
“Features and specifications” on page 4.
Note:
The speed of the fans will increase if:
v
One fan fails.
v
Ambient temperature gets too high.
Diagnosing errors
To find solutions to problems that have definite symptoms, see “Error symptoms”
on page 66.
If you cannot find the problem there, go to “Starting the diagnostic programs” on
page 14 to test the server.
Chapter 3. Diagnostics
21
Summary of Contents for xSeries 300
Page 1: ...Hardware Maintenance Manual xSeries 300 ...
Page 2: ......
Page 3: ...Hardware Maintenance Manual xSeries 300 ...
Page 10: ...2 Hardware Maintenance Manual xSeries 300 ...
Page 42: ...34 Hardware Maintenance Manual xSeries 300 ...
Page 93: ...Chapter 9 Related service information 85 ...
Page 94: ...86 Hardware Maintenance Manual xSeries 300 ...
Page 95: ...Chapter 9 Related service information 87 ...
Page 96: ...88 Hardware Maintenance Manual xSeries 300 ...
Page 97: ...Chapter 9 Related service information 89 ...
Page 98: ...90 Hardware Maintenance Manual xSeries 300 ...
Page 99: ...Chapter 9 Related service information 91 ...
Page 100: ...92 Hardware Maintenance Manual xSeries 300 ...
Page 110: ...102 Hardware Maintenance Manual xSeries 300 ...
Page 111: ...Chapter 9 Related service information 103 ...
Page 112: ...104 Hardware Maintenance Manual xSeries 300 ...
Page 119: ......