Solving
undetermined
problems
If
the
diagnostic
tests
did
not
diagnose
the
failure
or
if
the
server
is
inoperative,
use
the
information
in
this
section.
If
you
suspect
that
a
software
problem
is
causing
failures
(continuous
or
intermittent),
see
Damaged
data
in
CMOS
memory
or
damaged
BIOS
code
can
cause
undetermined
problems.
To
reset
the
CMOS
data,
use
the
CMOS
jumper
to
clear
the
CMOS
memory
and
override
the
power-on
password;
see
If
you
suspect
that
the
BIOS
code
is
damaged,
see
If
the
power
supplies
are
working
correctly,
complete
the
following
steps:
1.
Turn
off
the
server.
2.
Make
sure
that
the
server
is
cabled
correctly.
3.
Remove
or
disconnect
the
following
devices,
one
at
a
time,
until
you
find
the
failure.
Turn
on
the
server
and
reconfigure
it
each
time.
v
Any
external
devices.
v
Surge-suppressor
device
(on
the
server).
v
Modem,
printer,
mouse,
and
non-IBM
devices.
v
Each
adapter.
v
Hard
disk
drives.
v
Memory
modules.
The
minimum
configuration
requirement
is
512
MB
(one
512
MB
DIMM
in
DIMM
slot
1).
4.
Turn
on
the
server.
If
the
problem
is
solved
when
you
remove
an
adapter
from
the
server
but
the
problem
recurs
when
you
reinstall
the
same
adapter,
suspect
the
adapter;
if
the
problem
recurs
when
you
replace
the
adapter
with
a
different
one,
suspect
the
riser
card.
If
you
suspect
a
networking
problem
and
the
server
passes
all
the
system
tests,
suspect
a
network
cabling
problem
that
is
external
to
the
server.
Problem
determination
tips
Due
to
the
variety
of
hardware
and
software
combinations
that
can
be
encountered,
use
the
following
information
to
assist
you
in
problem
determination.
If
possible,
have
this
information
available
when
requesting
assistance
from
Service
Support
and
Engineering
functions.
v
Machine
type
and
model
v
Microprocessor
or
hard
disk
upgrades
v
Failure
symptom
–
Do
diagnostics
fail?
–
What,
when,
where,
single,
or
multiple
systems?
–
Is
the
failure
repeatable?
–
Has
this
configuration
ever
worked?
–
If
it
has
been
working,
what
changes
were
made
prior
to
it
failing?
–
Is
this
the
original
reported
failure?
v
Diagnostics
version
–
Type
and
version
level
110
IBM
xSeries
306m
Types
8849
and
8491:
Problem
Determination
and
Service
Guide
Summary of Contents for xSeries 206m
Page 1: ...IBM xSeries 306m Types 8849 and 8491 Problem Determination and Service Guide...
Page 2: ......
Page 3: ...IBM xSeries 306m Types 8849 and 8491 Problem Determination and Service Guide...
Page 8: ...vi IBM xSeries 306m Types 8849 and 8491 Problem Determination and Service Guide...
Page 143: ......
Page 144: ...Part Number 31R1183 Printed in USA 1P P N 31R1183...