v
[success] Reuwinterface expected - 4 interfaces found
v
[success] MAC address of interface ’eth10’ is 00:11:25:27:bf:e7
v
[success] Statistics for interface ’eth10’ show no errors
v
[success] 6 fans expected - 6 fans found
v
[success] fan 1 operating within expected range
v
[success] Status of the crypto ’standard’ is fully operational
Samples of
warning
statements are as follows:
v
[warning] Backtrace file exists.
v
[warning] Physical link on interface ’eth10’ is down.
v
[warning] eth10 has invalid MAC (ff:ff:ff:ff:ff)
Samples of
failure
statements are as follows:
v
[failure] Expected number of interfaces: 4 - Found: 1
v
[failure] fan 2 operating outside expected range (rpm too low)
v
[failure] Status of crypto ’not detected’ is unknown.
The output of the
test hardware
command is part of any generated error report.
Using the diagnostic self-test
The Type 7198 and 7199 appliance provides a boot-time diagnostic self-test to help
you test hardware components.
Note:
Only use the diagnostic self-test when directed by IBM Support to help
confirm a potential hardware problem with the appliance.
To initialize the diagnostic self-test:
1.
Connect the serial cable.
2.
If the appliance is not turned on, press the power button to turn on the
appliance. The green power LED will illuminate. You should hear the fans start
up.
3.
When you see
DPOS boot - press <ESC> within 7 seconds for boot options
,
press ESC with seven seconds. You should see the
DPOS
prompt followed by the
boot options menu.
DPOS boot - press <ESC> within 7 seconds for boot options.. <ESC>
DPOS> ?
Available DataPower boot options:
Boot Option
Description
------------
------------------------------------------
system
Normal System Startup
diagnostics
Run Standalone Hardware Diagnostics
DPOS>
4.
At the
DPOS
prompt, enter
diagnostics
to start the appliance and display the
diagnostics main menu.
34
Installation and User's Guide
Summary of Contents for WebSphere DataPower 7198
Page 1: ...WebSphere DataPower Type 7198 and 7199 Third Edition Installation and User s Guide...
Page 2: ......
Page 3: ...WebSphere DataPower Type 7198 and 7199 Third Edition Installation and User s Guide...
Page 16: ...xiv Installation and User s Guide...
Page 20: ...xviii Installation and User s Guide...
Page 36: ...16 Installation and User s Guide...
Page 50: ...30 Installation and User s Guide...
Page 87: ......
Page 88: ...Part Number 97Y0541 Printed in USA 1P P N 97Y0541...