Removing or replacing a spooling mechanism
Occasionally, only the robotic spooling cable must be removed and replaced. See “Identifying a failed
1. Power down the library.
Important: Under normal circumstances, when the library is powered off by using the front Power,
the robot automatically parks and locks into the Base Module behind the Operator Panel. If you are
given a choice during the power down procedure, choose the default park position. To protect the
spooling cable or other sensitive parts, the accessor must be in the Base Module before any
components are removed from the library. If it is not, follow the procedure for returning the accessor
to the base module. See “Returning the accessor to the Base Module” on page 141.
2. Refer to “Preparing to remove the accessor and spooling mechanism from the Base Module” on page
135 for the steps in preparing your library.
3. Remove the left magazine to provide clear access to the spooling mechanism.
4. Follow the steps in “Removing the accessor and spooling mechanism from the Base Module” on page
136 to remove the accessor, disconnect the spooling cable, and place it in the park position.
5. Push down on the lever on the top of the spooling mechanism (
1
) and slide about 10 mm towards the
center (
2
) to unlock the mechanism.
Chapter 6. Upgrading and servicing 143
Summary of Contents for TS4300 3555
Page 1: ...IBM TS4300 Tape Library Machine Type 3555 User s Guide IBM SC27 4629 07...
Page 66: ...Chapter 3 Installing 36 IBM TS4300 Tape Library Machine Type 3555 User s Guide...
Page 77: ...Figure 38 Mounting the rails to the connectors Chapter 3 Installing 47...
Page 175: ...Figure 81 Unlocked spooling mechanism enlarged view Chapter 6 Upgrading and servicing 145...
Page 261: ......
Page 262: ...IBM SC27 4629 07...