pool.
You
choose
how
each
group
is
made
up,
and
you
can
combine
managed
disks
from
different
manufacturers’
controllers
in
the
same
managed
disk
group
if
required.
Note:
Some
operating
systems
cannot
tolerate
other
operating
systems
in
the
same
zone.
You
can
remove
one
node
in
each
I/O
group
from
a
cluster
when
hardware
service
or
maintenance
is
required.
After
you
remove
the
node,
you
can
replace
the
field
replaceable
units
(FRUs)
in
the
node.
All
disk
drive
communication
and
communication
between
nodes
is
performed
through
the
SAN.
All
SAN
Volume
Controller
configuration
and
service
commands
are
sent
to
the
cluster
through
an
Ethernet
network.
Each
node
contains
its
own
vital
product
data
(VPD).
Each
cluster
contains
VPD
that
is
common
to
all
the
nodes
on
the
cluster,
and
any
system
connected
to
the
Ethernet
network
can
access
this
VPD.
Cluster
configuration
information
is
stored
on
every
node
that
is
in
the
cluster
to
allow
concurrent
replacement
of
FRUs.
An
example
of
this
information
might
be
information
that
is
displayed
on
the
menu
screen
of
the
SAN
Volume
Controller.
When
a
new
FRU
is
installed
and
when
the
node
is
added
back
into
the
cluster,
configuration
information
that
is
required
by
that
node
is
read
from
other
nodes
in
the
cluster.
SAN
Volume
Controller
operating
environment
v
Minimum
of
one
pair
of
SAN
Volume
Controller
nodes
v
Minimum
of
two
uninterruptible
power
supplies
Fibre Channel
Fabric
Host
Host
Host
Host
SAN Volume
Controller
.
.
.
RAID
RAID
RAID
RAID
. . .
Host zone
Disk zone
SAN Volume
Controller
SAN Volume
Controller
Figure
5.
Example
of
a
SAN
Volume
Controller
in
a
fabric
Chapter
1.
Overview
of
the
SAN
Volume
Controller
3
Summary of Contents for TotalStorage SAN Volume Controller
Page 1: ...IBM TotalStorage SAN Volume Controller Installation Guide V ersion 2 1 0 SC26 7541 04...
Page 2: ......
Page 3: ...IBM TotalStorage SAN Volume Controller Installation Guide V ersion 2 1 0 SC26 7541 04...
Page 8: ...vi IBM TotalStorage SAN Volume Controller Installation Guide...
Page 10: ...viii IBM TotalStorage SAN Volume Controller Installation Guide...
Page 11: ...Tables 1 Uninterruptible power supply support guidelines 17 Copyright IBM Corp 2003 2005 ix...
Page 12: ...x IBM TotalStorage SAN Volume Controller Installation Guide...
Page 30: ...xxviii IBM TotalStorage SAN Volume Controller Installation Guide...
Page 44: ...14 IBM TotalStorage SAN Volume Controller Installation Guide...
Page 62: ...32 IBM TotalStorage SAN Volume Controller Installation Guide...
Page 102: ...72 IBM TotalStorage SAN Volume Controller Installation Guide...
Page 108: ...78 IBM TotalStorage SAN Volume Controller Installation Guide...
Page 114: ...84 IBM TotalStorage SAN Volume Controller Installation Guide...
Page 121: ......
Page 122: ...Part Number 64P8289 Printed in USA SC26 7541 04 1P P N 64P8289...
Page 123: ...Spine information IBM TotalStorage SAN Volume Controller Installation Guide Version 2 1 0...